Difference between revisions of "User:Jhurley/sandbox"

From Enviro Wiki
Jump to: navigation, search
(→‎PFAS Background)
 
(202 intermediate revisions by the same user not shown)
Line 1: Line 1:
−
==Lysimeters for Measuring PFAS Concentrations in the Vadose Zone==  
+
==Thermal In Situ Sustainable Remediation to Enhance Biotic and Abiotic Reactions and Accelerate Remediation Timeframes==  
−
[[Perfluoroalkyl and Polyfluoroalkyl Substances (PFAS) | PFAS]] are frequently introduced to the environment through soil surface applications which then transport through the vadose zone to reach underlying groundwater receptors. Due to their unique properties and resulting transport and retention behaviors, PFAS in the vadose zone can be a persistent contaminant source to underlying groundwater systems. Determining the fraction of PFAS present in the mobile porewater relative to the total concentrations in soils is critical to understanding the risk posed by PFAS in vadose zone source areas. Lysimeters are instruments that have been used by agronomists and vadose zone researchers for decades to determine water flux and solute concentrations in unsaturated porewater. Lysimeters have recently been developed as a critical tool for field investigations and characterizations of PFAS impacted source zones.  
+
Thermal In Situ Sustainable Remediation (TISR<sup>®</sup>; US Pat. Nos. 10,384,246 and 10,688,545) is a cost-effective and adaptable low temperature thermal remediation technology that accelerates contaminant treatment. It achieves this by enhancing biotic and abiotic contaminant degradation rates through a modest increase in subsurface temperature. TISR<sup>®</sup> is suitable for a wide range of hydrogeologic settings. It also offers reduced operational costs, a lower carbon footprint, and possibly shorter remedial timeframes than more conventional methods.
 
<div style="float:right;margin:0 0 2em 2em;">__TOC__</div>
 
<div style="float:right;margin:0 0 2em 2em;">__TOC__</div>
  
 
'''Related Article(s):'''
 
'''Related Article(s):'''
  
−
*[[Perfluoroalkyl and Polyfluoroalkyl Substances (PFAS)]]
+
*[[Thermal Remediation]]
−
*[[PFAS Transport and Fate]]
+
*[[Thermal Remediation - Electrical Resistance Heating | Electrical Resistance Heating]]
 +
*[[Thermal Conduction Heating (TCH)]]
 +
*[[Thermal Remediation - Combined Remedies | Combined Remedies]]
  
−
'''Contributors:''' Gorm Heron, Emily Crownover, Patrick Joyce, Ramona Iery
+
'''Contributors:''' Jonah Munholland, Julia Vidonish, and Craig Divine
  
−
'''Key Resource:'''
+
'''Key Resources:'''
−
*Perfluoroalkyl and polyfluoroalkyl substances thermal desorption evaluation
+
*Thermal In Situ Sustainable Remediation to Enhance Biotic and Abiotic Reactions and Accelerate Remediation Timeframes, Final Report. ESTCP Project ER20-5028<ref>Divine, C., Munholland, J., Zardouzian, E., Justicia-Leon, S., Aspinall, J.V., Randhawa, D., Falta, R., Freedman, D., Becker, M., 2025. Thermal In Situ Sustainable Remediation to Enhance Biotic and Abiotic Reactions and Accelerate Remediation Timeframes, Final Report. Environmental Security Technology Certification Program (ESTCP), Project ER20-5028. [https://serdp-estcp.mil/projects/details/bab4bc87-b4bc-42df-ad0e-11ea0adf27dc/er20-5028-project-overview Project Website]&nbsp; [[Media: ER20-5028 FR DevineEtAl2025.pdf | Final Report.pdf]]</ref>.
 +
 
 +
*Advances in Low-Temperature Thermal Remediation. Munholland ''et al.'', 2024<ref name="MunhollandEtAl2024">Munholland, J, Rosso, D., Randhawa, D., Devine, C., Pennington, A., 2024. Advances in Low-Temperature Thermal Remediation. In: García-Rincón, J., Gatsios, E., Lenhard, R.J., Atekwana, E.A., Naidu, R. (eds), Advances in the Characterisation and Remediation of Sites Contaminated with Petroleum Hydrocarbons, Chapter 18 pp. 623-653. Environmental Contamination Remediation and Management series, Springer Nature. [https://doi.org/10.1007/978-3-031-34447-3_18 doi: 10.1007/978-3-031-34447-3_18]&nbsp; [[Media: MunhollandEtAl2024.pdf | Open Access Chapter]]</ref>.
 +
 
 +
*A Design Tool for Solar Thermal Remediation Using Borehole Heat Exchangers. Ornelles, Falta, and Divine, 2023<ref name="Ornelles">Ornelles, A.D., Falta, R.W., Divine, C.E., 2023. A Design Tool for Solar Thermal Remediation Using Borehole Heat Exchangers. Ground Water, 61(2), pp. 245-254. [https://doi.org/10.1111/gwat.13265 doi: 10.1111/gwat.13265]&nbsp; [https://ngwa.onlinelibrary.wiley.com/doi/epdf/10.1111/gwat.13265 Free download from NGWA]</ref>.
 +
 
 +
*Low-Temperature Thermal Remediation: Gaining Traction as a Green Remedial Alternative. Horst, ''et al.'', 2018<ref name="HorstEtAl2018">Horst, J., Flanders, C., Klemmer, M., Randhawa, D.S., Rosso, D., 2018. Low-Temperature Thermal Remediation: Gaining Traction as a Green Remedial Alternative. Groundwater Monitoring and Remediation, 38(3), pp. 18-27. [https://doi.org/10.1111/gwmr.12295 doi: 10.1111/gwmr.12295]</ref>.
  
 
==Introduction==
 
==Introduction==
−
Lysimeters are devices that are placed in the subsurface above the groundwater table to monitor the movement of water through the soil<ref name="GossEhlers2009">Goss, M.J., Ehlers, W., 2009. The Role of Lysimeters in the Development of Our Understanding of Soil Water and Nutrient Dynamics in Ecosystems. Soil Use and Management, 25(3), pp. 213–223. [https://doi.org/10.1111/j.1475-2743.2009.00230.x doi: 10.1111/j.1475-2743.2009.00230.x]</ref><ref>Pütz, T., Fank, J., Flury, M., 2018. Lysimeters in Vadose Zone Research. Vadose Zone Journal, 17 (1), pp. 1-4. [https://doi.org/10.2136/vzj2018.02.0035 doi: 10.2136/vzj2018.02.0035]&nbsp; [[Media: PutzEtAl2018.pdf | Open Access Article]]</ref><ref name="CostanzaEtAl2025">Costanza, J., Clabaugh, C.D., Leibli, C., Ferreira, J., Wilkin, R.T., 2025. Using Suction Lysimeters for Determining the Potential of Per- and Polyfluoroalkyl Substances to Leach from Soil to Groundwater: A Review. Environmental Science and Technology, 59(9), pp. 4215-4229. [https://doi.org/10.1021/acs.est.4c10246 doi: 10.1021/acs.est.4c10246]</ref>. Lysimeters have historically been used in agricultural sciences for monitoring nutrient or contaminant movement, soil moisture release curves, natural drainage patterns, and dynamics of plant-water interactions<ref name="GossEhlers2009"/><ref>Bergström, L., 1990. Use of Lysimeters to Estimate Leaching of Pesticides in Agricultural Soils. Environmental Pollution, 67 (4), 325–347. [https://doi.org/10.1016/0269-7491(90)90070-S doi: 10.1016/0269-7491(90)90070-S]</ref><ref>Dabrowska, D., Rykala, W., 2021. A Review of Lysimeter Experiments Carried Out on Municipal Landfill Waste. Toxics, 9(2), Article 26. [https://doi.org/10.3390/toxics9020026 doi: 10.3390/toxics9020026]&nbsp; [[Media: Dabrowska Rykala2021.pdf | Open Access Article]]</ref><ref>Fernando, S.U., Galagedara, L., Krishnapillai, M., Cuss, C.W., 2023. Lysimeter Sampling System for Optimal Determination of Trace Elements in Soil Solutions. Water, 15(18), Article 3277. [https://doi.org/10.3390/w15183277 doi: 10.3390/w15183277]&nbsp; [[Media: FernandoEtAl2023.pdf | Open Access Article]]</ref><ref name="MeissnerEtAl2020">Meissner, R., Rupp, H., Haselow, L., 2020. Use of Lysimeters for Monitoring Soil Water Balance Parameters and Nutrient Leaching. In: Climate Change and Soil Interactions. Elsevier, pp. 171-205. [https://doi.org/10.1016/B978-0-12-818032-7.00007-2 doi: 10.1016/B978-0-12-818032-7.00007-2]</ref><ref name="RogersMcConnell1993">Rogers, R.D., McConnell, J.W. Jr., 1993. Lysimeter Literature Review, Nuclear Regulatory Commission Report Numbers: NUREG/CR--6073, EGG--2706. [https://www.osti.gov/] ID: 10183270. [https://doi.org/10.2172/10183270 doi: 10.2172/10183270]&nbsp; [[Media: RogersMcConnell1993.pdf | Open  Access Article]]</ref><ref>Sołtysiak, M., Rakoczy, M., 2019. An Overview of the Experimental Research Use of Lysimeters. Environmental and Socio-Economic Studies, 7(2), pp. 49-56. [https://doi.org/10.2478/environ-2019-0012 doi: 10.2478/environ-2019-0012]&nbsp; [[Media: SołtysiakRakoczy2019.pdf | Open Access Article]]</ref><ref name="Stannard1992">Stannard, D.I., 1992. Tensiometers—Theory, Construction, and Use. Geotechnical Testing Journal, 15(1), pp. 48-58. [https://doi.org/10.1520/GTJ10224J doi: 10.1520/GTJ10224J]</ref><ref name="WintonWeber1996">Winton, K., Weber, J.B., 1996. A Review of Field Lysimeter Studies to Describe the Environmental Fate of Pesticides. Weed Technology, 10(1), pp. 202-209. [https://doi.org/10.1017/S0890037X00045929 doi: 10.1017/S0890037X00045929]</ref>. Recently, there has been strong interest in the use of lysimeters to measure and monitor movement of per- and polyfluoroalkyl substances (PFAS) through the vadose zone<ref name="Anderson2021">Anderson, R.H., 2021. The Case for Direct Measures of Soil-to-Groundwater Contaminant Mass Discharge at AFFF-Impacted Sites. Environmental Science and Technology, 55(10), pp. 6580-6583. [https://doi.org/10.1021/acs.est.1c01543 doi: 10.1021/acs.est.1c01543]</ref><ref name="AndersonEtAl2022">Anderson, R.H., Feild, J.B., Dieffenbach-Carle, H., Elsharnouby, O., Krebs, R.K., 2022. Assessment of PFAS in Collocated Soil and Porewater Samples at an AFFF-Impacted Source Zone: Field-Scale Validation of Suction Lysimeters. Chemosphere, 308(1), Article 136247. [https://doi.org/10.1016/j.chemosphere.2022.136247 doi: 10.1016/j.chemosphere.2022.136247]</ref><ref name="SchaeferEtAl2024">Schaefer, C.E., Nguyen, D., Fang, Y., Gonda, N., Zhang, C., Shea, S., Higgins, C.P., 2024. PFAS Porewater Concentrations in Unsaturated Soil: Field and Laboratory Comparisons Inform on PFAS Accumulation at Air-Water Interfaces. Journal of Contaminant Hydrology, 264, Article 104359. [https://doi.org/10.1016/j.jconhyd.2024.104359 doi: 10.1016/j.jconhyd.2024.104359]&nbsp; [[Media: SchaeferEtAl2024.pdf | Open Access Manuscript]]</ref><ref name="SchaeferEtAl2023">Schaefer, C.E., Lavorgna, G.M., Lippincott, D.R., Nguyen, D., Schaum, A., Higgins, C.P., Field, J., 2023. Leaching of Perfluoroalkyl Acids During Unsaturated Zone Flushing at a Field Site Impacted with Aqueous Film Forming Foam. Environmental Science and Technology, 57(5), pp. 1940-1948. [https://doi.org/10.1021/acs.est.2c06903 doi: 10.1021/acs.est.2c06903]</ref><ref name="SchaeferEtAl2022">Schaefer, C.E., Lavorgna, G.M., Lippincott, D.R., Nguyen, D., Christie, E., Shea, S., O’Hare, S., Lemes, M.C.S., Higgins, C.P., Field, J., 2022. A Field Study to Assess the Role of Air-Water Interfacial Sorption on PFAS Leaching in an AFFF Source Area. Journal of Contaminant Hydrology, 248, Article 104001. [https://doi.org/10.1016/j.jconhyd.2022.104001 doi: 10.1016/j.jconhyd.2022.104001]&nbsp; [[Media: SchaeferEtAl2022.pdf | Open Access Manuscript]]</ref><ref name="QuinnanEtAl2021">Quinnan, J., Rossi, M., Curry, P., Lupo, M., Miller, M., Korb, H., Orth, C., Hasbrouck, K., 2021. Application of PFAS-Mobile Lab to Support Adaptive Characterization and Flux-Based Conceptual Site Models at AFFF Releases. Remediation, 31(3), pp. 7-26. [https://doi.org/10.1002/rem.21680 doi: 10.1002/rem.21680]</ref>. PFAS are frequently introduced to the environment through land surface application and have been found to be strongly retained within the upper 5 feet of soil<ref name="BrusseauEtAl2020">Brusseau, M.L., Anderson, R.H., Guo, B., 2020. PFAS Concentrations in Soils: Background Levels versus Contaminated Sites. Science of The Total Environment, 740, Article 140017. [https://doi.org/10.1016/j.scitotenv.2020.140017 doi: 10.1016/j.scitotenv.2020.140017]</ref><ref name="BiglerEtAl2024">Bigler, M.C., Brusseau, M.L., Guo, B., Jones, S.L., Pritchard, J.C., Higgins, C.P., Hatton, J., 2024. High-Resolution Depth-Discrete Analysis of PFAS Distribution and Leaching for a Vadose-Zone Source at an AFFF-Impacted Site. Environmental Science and Technology, 58(22), pp. 9863-9874. [https://doi.org/10.1021/acs.est.4c01615 doi: 10.1021/acs.est.4c01615]</ref>. PFAS recalcitrance in the vadose zone means that environmental program managers and consultants need a cost-effective way of monitoring concentration conditions within the vadose zone. Repeated soil sampling and extraction processes are time consuming and only give a representative concentration of total PFAS in the matrix<ref name="NickersonEtAl2020">Nickerson, A., Maizel, A.C., Kulkarni, P.R., Adamson, D.T., Kornuc, J. J., Higgins, C.P., 2020. Enhanced Extraction of AFFF-Associated PFASs from Source Zone Soils. Environmental Science and Technology, 54(8), pp. 4952-4962. [https://doi.org/10.1021/acs.est.0c00792 doi: 10.1021/acs.est.0c00792]</ref>, not what is readily transportable in mobile porewater<ref name="SchaeferEtAl2023"/><ref name="StultsEtAl2024">Stults, J.F., Schaefer, C.E., Fang, Y., Devon, J., Nguyen, D., Real, I., Hao, S., Guelfo, J.L., 2024. Air-Water Interfacial Collapse and Rate-Limited Solid Desorption Control Perfluoroalkyl Acid Leaching from the Vadose Zone. Journal of Contaminant Hydrology, 265, Article 104382. [https://doi.org/10.1016/j.jconhyd.2024.104382 doi: 10.1016/j.jconhyd.2024.104382]&nbsp; [[Media: StultsEtAl2024.pdf | Open Access Manuscript]]</ref><ref name="StultsEtAl2023">Stults, J.F., Choi, Y.J., Rockwell, C., Schaefer, C.E., Nguyen, D.D., Knappe, D.R.U., Illangasekare, T.H., Higgins, C.P., 2023. Predicting Concentration- and Ionic-Strength-Dependent Air–Water Interfacial Partitioning Parameters of PFASs Using Quantitative Structure–Property Relationships (QSPRs). Environmental Science and Technology, 57(13), pp. 5203-5215. [https://doi.org/10.1021/acs.est.2c07316 doi: 10.1021/acs.est.2c07316]</ref><ref name="BrusseauGuo2022">Brusseau, M.L., Guo, B., 2022. PFAS Concentrations in Soil versus Soil Porewater: Mass Distributions and the Impact of Adsorption at Air-Water Interfaces. Chemosphere, 302, Article 134938. [https://doi.org/10.1016/j.chemosphere.2022.134938 doi: 10.1016/j.chemosphere.2022.134938]&nbsp; [[Media: BrusseauGuo2022.pdf | Open Access Manuscript]]</ref>. Fortunately, lysimeters have been found to be a viable option for monitoring the concentration of PFAS in the mobile porewater phase in the vadose zone<ref name="Anderson2021"/><ref name="AndersonEtAl2022"/>. Note that while some lysimeters, known as weighing lysimeters, can directly measure water flux, the most commonly utilized lysimeters in PFAS investigations only provide measurements of porewater concentrations.
+
[[File: MunhollandFig1.png | thumb | 500 px | Figure 1: Components and layout of a TISR<sup>®</sup> system]]
 +
TISR<sup>®</sup> utilizes [[Wikipedia: Downhole heat exchanger | borehole heat exchangers (BHEs)]] to heat target treatment areas in the subsurface. This is achieved through a combination of solar collectors, which harness solar radiation as heat, and the utilization of other heat sources such as waste heat or hybrid heating with heat pumps. That heat is then transferred to the subsurface via a closed loop circulation system connected to the BHEs (Figure 1). By incorporating these additional heat sources, TISR<sup>®</sup> ensures a more robust and constant heat supply, enabling customization of the system to address specific site challenges and facilitate efficient heat transfer.
 +
 
 +
The heating of the subsurface through TISR<sup>®</sup> accelerates various processes such as biodegradation, abiotic reactions, and contaminant desorption and dissolution. The technology is also suitable for diverse hydrogeologic environments, including sites with low permeability zones, due to the relatively uniform thermal conductivity of geologic materials, which is unaffected by grain size<ref name="MunhollandEtAl2024"/>. This versatility allows TISR<sup>®</sup> to integrate with conventional remediation technologies, enhancing their performance.
 +
 
 +
One of the key advantages of TISR<sup>®</sup> is its ability to accelerate treatment processes while minimizing energy consumption. By harnessing renewable and sustainable energy sources such as solar radiation and effectively utilizing waste heat or hybrid heating with heat pumps, TISR<sup>®</sup> delivers an efficient, cost-effective remediation solution. Compatibility with multiple conventional remediation technologies makes it an effective option for addressing a variety of contamination challenges.
 +
 
 +
==Scientific Principles==
 +
[[File: MunhollandFig2.png | thumb | 500 px | Figure 2: Effect of temperature on hydrolysis rates for VOCs]]
 +
During the TISR<sup>®</sup> heating process, thermal conduction and advection play a crucial role in boosting physical, biological, and chemical processes within the treatment zones, leading to enhanced attenuation, degradation, and removal of contaminants from the subsurface<ref>Dettmer, K., 2002. A Discussion of the Effects of Thermal Remediation Treatments on Microbial Degradation Processes. U.S. Environmental Protection Agency, Office of Solid Waste and Emergency Response, Technology Innovation Office, Washington, DC. [[Media: dettmer2002.pdf | free report]]&nbsp; [https://www.clu-in.org/download/techdrct/dettmer.pdf free download from clu-in.org]</ref><ref name="HorstEtAl2018"/>. TISR<sup>®</sup> systems are typically designed to enhance the biological activity and performance of other active technologies, such as [[Wikipedia: Air sparging | air sparge]]/[[Soil Vapor Extraction (SVE) | soil vapor extraction]] (AS/SVE) or [[Chemical Oxidation (In Situ - ISCO) | chemical oxidation]], by increasing the subsurface temperature by approximately 10°C to 20°C. The target groundwater temperature is often set to reach up to about 35°C, which is the optimal temperature for promoting the activity of mesophilic microbial communities responsible for biodegradation of certain contaminants. In cases where the objective is to maximize abiotic hydrolysis mechanisms, such as for some chlorinated alkanes, TISR<sup>®</sup> systems can be designed to reach a final groundwater temperature of up to 60°C.
  
−
==PFAS Background==
+
The effectiveness of TISR<sup>®</sup> in enhancing treatment performance has been demonstrated through several mechanisms, which are discussed below:
−
PFAS are a broad class of chemicals with highly variable chemical structures<ref>Moody, C.A., Field, J.A., 1999. Determination of Perfluorocarboxylates in Groundwater Impacted by Fire-Fighting Activity. Environmental Science and Technology, 33(16), pp. 2800-2806. [https://doi.org/10.1021/es981355+ doi: 10.1021/es981355+]</ref><ref name="MoodyField2000">Moody, C.A., Field, J.A., 2000. Perfluorinated Surfactants and the Environmental Implications of Their Use in Fire-Fighting Foams. Environmental Science and Technology, 34(18), pp. 3864-3870. [https://doi.org/10.1021/es991359u doi: 10.1021/es991359u]</ref><ref name="GlügeEtAl2020">Glüge, J., Scheringer, M., Cousins, I.T., DeWitt, J.C., Goldenman, G., Herzke, D., Lohmann, R., Ng, C.A., Trier, X., Wang, Z., 2020. An Overview of the Uses of Per- and Polyfluoroalkyl Substances (PFAS). Environmental Science: Processes and Impacts, 22(12), pp. 2345-2373. [https://doi.org/10.1039/D0EM00291G doi: 10.1039/D0EM00291G]&nbsp; [[Media: GlügeEtAl2020.pdf | Open Access Article]]</ref>. One characteristic feature of PFAS is that they are fluorosurfactants, distinct from more traditional hydrocarbon surfactants<ref name="MoodyField2000"/><ref name="Brusseau2018">Brusseau, M.L., 2018. Assessing the Potential Contributions of Additional Retention Processes to PFAS Retardation in the Subsurface. Science of The Total Environment, 613-614, pp. 176-185. [https://doi.org/10.1016/j.scitotenv.2017.09.065 doi: 10.1016/j.scitotenv.2017.09.065]&nbsp; [[Media: Brusseau2018.pdf | Open Access Manuscript]]</ref><ref>Dave, N., Joshi, T., 2017. A Concise Review on Surfactants and Its Significance. International Journal of Applied Chemistry, 13(3), pp. 663-672. [https://doi.org/10.37622/IJAC/13.3.2017.663-672 doi: 10.37622/IJAC/13.3.2017.663-672]&nbsp; [[Media: DaveJoshi2017.pdf  | Open Access Article]]</ref><ref>García, R.A., Chiaia-Hernández, A.C., Lara-Martin, P.A., Loos, M., Hollender, J., Oetjen, K., Higgins, C.P., Field, J.A., 2019. Suspect Screening of Hydrocarbon Surfactants in Afffs and Afff-Contaminated Groundwater by High-Resolution Mass Spectrometry. Environmental Science and Technology, 53(14), pp. 8068-8077. [https://doi.org/10.1021/acs.est.9b01895 doi: 10.1021/acs.est.9b01895]</ref>. Fluorosurfactants typically have a fully or partially fluorinated, hydrophobic tail with ionic (cationic, zwitterionic, or anionic) head group that is hydrophilic<ref name="MoodyField2000"/><ref name="GlügeEtAl2020"/>. The hydrophobic tail and ionic head group mean PFAS are very stable at hydrophobic adsorption interfaces when present in the aqueous phase<ref>Krafft, M.P., Riess, J.G., 2015. Per- and Polyfluorinated Substances (PFASs): Environmental Challenges. Current Opinion in Colloid and Interface Science, 20(3), pp. 192-212. [https://doi.org/10.1016/j.cocis.2015.07.004 doi: 10.1016/j.cocis.2015.07.004]</ref>. Examples of these interfaces include naturally occurring organic matter in soils and the air-water interface in the vadose zone<ref>Schaefer, C.E., Culina, V., Nguyen, D., Field, J., 2019. Uptake of Poly- and Perfluoroalkyl Substances at the Air–Water Interface. Environmental Science and Technology, 53(21), pp. 12442-12448. [https://doi.org/10.1021/acs.est.9b04008 doi: 10.1021/acs.est.9b04008]</ref><ref>Lyu, Y., Brusseau, M.L., Chen, W., Yan, N., Fu, X., Lin, X., 2018. Adsorption of PFOA at the Air–Water Interface during Transport in Unsaturated Porous Media. Environmental Science and Technology, 52(14), pp. 7745-7753. [https://doi.org/10.1021/acs.est.8b02348 doi: 10.1021/acs.est.8b02348]</ref><ref>Costanza, J., Arshadi, M., Abriola, L.M., Pennell, K.D., 2019. Accumulation of PFOA and PFOS at the Air-Water Interface. Environmental Science and Technology Letters, 6(8), pp. 487-491. [https://doi.org/10.1021/acs.estlett.9b00355 doi: 10.1021/acs.estlett.9b00355]</ref><ref>Li, F., Fang, X., Zhou, Z., Liao, X., Zou, J., Yuan, B., Sun, W., 2019. Adsorption of Perfluorinated Acids onto Soils: Kinetics, Isotherms, and Influences of Soil Properties. Science of The Total Environment, 649, pp. 504-514. [https://doi.org/10.1016/j.scitotenv.2018.08.209 doi: 10.1016/j.scitotenv.2018.08.209]</ref><ref>Nguyen, T.M.H., Bräunig, J., Thompson, K., Thompson, J., Kabiri, S., Navarro, D.A., Kookana, R.S., Grimison, C., Barnes, C.M., Higgins, C.P., McLaughlin, M.J., Mueller, J.F., 2020. Influences of Chemical Properties, Soil Properties, and Solution pH on Soil–Water Partitioning Coefficients of Per- and Polyfluoroalkyl Substances (PFASs). Environmental Science and Technology, 54(24), pp. 15883-15892. [https://doi.org/10.1021/acs.est.0c05705 doi: 10.1021/acs.est.0c05705]&nbsp; [[Media: NguyenEtAl2020.pdf  | Open Access Article]]</ref>. Their strong adsorption to both soil organic matter and the air-water interface is a major contributor to elevated concentrations of PFAS observed in the upper 5 feet of the soil column<ref name="BrusseauEtAl2020"/><ref name="BiglerEtAl2024"/>. While several other PFAS partitioning processes exist<ref name="Brusseau2018"/>, adsorption to solid phase soils and air-water interfaces are the two primary processes present at nearly all PFAS sites<ref>Brusseau, M.L., Yan, N., Van Glubt, S., Wang, Y., Chen, W., Lyu, Y., Dungan, B., Carroll, K.C., Holguin, F.O., 2019. Comprehensive Retention Model for PFAS Transport in Subsurface Systems. Water Research, 148, pp. 41-50. [https://doi.org/10.1016/j.watres.2018.10.035 doi: 10.1016/j.watres.2018.10.035]</ref>. The total PFAS mass obtained from a vadose zone soil sample contains the solid phase, air-water interfacial, and aqueous phase PFAS mass, which can be converted to porewater concentrations using Equation 1<ref name="BrusseauGuo2022"/>.</br>
 
−
:''Equation 1:''
 
  
−
==Heating Method==
+
*Primary dechlorinating bacteria, such as [[Wikipedia: Dehalococcoides | Dehalococcoides]] and [[Wikipedia: Dehalogenimonas | Dehalogenimonas]], are known to be [[Wikipedia: Mesophile | mesophilic]]. Therefore, increasing the temperature can significantly enhance microbial activity and biodegradation by multiple orders of magnitude<ref>Macbeth, T., Truex, M., Powell, T., Michalsen, M., 2012. Combining Low-Energy Electrical Resistance Heating with Biotic and Abiotic Reactions for Treatment of Chlorinated Solvent DNAPL Source Areas. [https://serdp-estcp.mil/ Environmental Security Technology Certification Program (ESTCP)] [https://serdp-estcp.mil/projects/details/877a3b41-6bed-4f4a-b43a-87fbcd9b7f0b/er-200719-project-overview Project ER-200719 webpage]&nbsp; [[Media: Macbeth2012_ER-200719-FR.pdf | free download]]&nbsp; [https://www.youtube.com/watch?v=-EbwKbs8scE Project Summary Presentation]</ref>.
−
For semi-volatile compounds such as dioxins, furans, poly-chlorinated biphenyls (PCBs) and Poly-Aromatic Hydrocarbons (PAH), thermal conduction heating has evolved as the dominant thermal technology because it is capable of achieving soil temperatures higher than the boiling point of water, which are necessary for complete removal of these organic compounds. Temperatures between 200 and 500&deg;C have been required to achieve the desired reduction in contaminant concentrations<ref name="StegemeierVinegar2001">Stegemeier, G.L., Vinegar, H.J., 2001. Thermal Conduction Heating for In-Situ Thermal Desorption of Soils. Ch. 4.6, pp. 1-37. In: Chang H. Oh (ed.), Hazardous and Radioactive Waste Treatment Technologies Handbook, CRC Press, Boca Raton, FL. ISBN 9780849395864 [[Media: StegemeierVinegar2001.pdf | Open Access Article]]</ref>. TCH has become a popular technology for PFAS treatment because temperatures in the 400&deg;C range are needed.
 
  
−
The energy source for TCH can be electricity (most commonly used), or fossil fuels (typically gas, diesel or fuel oil). Electrically powered TCH offers the largest flexibility for power input which also can be supplied by renewable and sustainable energy sources.
+
*Reduced iron minerals, particularly iron sulfides, can participate in the abiotic degradation of chlorinated ethenes and other contaminants. The rates of these reactions generally depend on temperature, following the [[Wikipedia: Arrhenius equation | Arrhenius equation]].
  
−
==Energy Usage==
+
*[[Wikipedia: Hydrolysis | Hydrolysis]] rates for certain compounds exhibit high temperature dependence. For example, a 10°C increase can lead to a 50% reduction in the half-life of [[Wikipedia: 1,1,1-Trichloroethane | 1,1,1-trichloroethane (1,1,1-TCA)]]<ref>Suthersan, S., Horst, J., Klemmer, M., Malone, D., 2012. Temperature-Activated Auto-Decomposition Reactions: An Under-Utilized In Situ Remediation Solution. Groundwater Monitoring and Remediation, 32(3), pp. 34-40. [https://doi.org/10.1111/j.1745-6592.2012.01407.x doi: 10.1111/j.1745-6592.2012.01407.x]</ref>. Figure 2 presents the calculated temperature-dependent hydrolysis rates for 13 common [[Wikipedia: Volatile organic compound | volatile organic compounds (VOCs)]] at a pH of 7.
−
Treating PFAS-impacted soil with heat requires energy to first bring the soil and porewater to the boiling point of water, then to evaporate the porewater until the soil is dry, and finally to heat the dry soil up to the target treatment temperature. The energy demand for wet soils falls in the 300-400 kWh/cy range, dependent on porosity and water saturation. Additional energy is consumed as heat is lost to the surroundings and by vapor treatment equipment, yielding a typical usage of 400-600 kWh/cy total for larger soil treatment volumes. Wetter soils and small treatment volumes drive the energy usage towards the higher number, whereas larger soil volumes and dry soil can be treated with less energy.
 
  
−
==Vapor Treatment==
+
*[[Wikipedia: Henry's law | Henry's Law]] constant, [[Wikipedia: Vapor pressure | vapor pressure]], solubility, and viscosity values are also temperature dependent. For instance, the Henry's Law constant values for many VOCs, including [[Wikipedia: Tetrachloroethylene | tetrachloroethene (PCE)]], have been observed to double between 8 and 24°C<ref>Chen, F., Freedman, D.L., Falta, R.W., Murdoch, L.C., 2012. Henry's law constants of chlorinated solvents at elevated temperatures. Chemosphere, 86(2), pp.156-165. [https://doi.org/10.1016/j.chemosphere.2011.10.004 doi: 10.1016/j.chemosphere.2011.10.004]</ref>.
−
During the TCH process a significant fraction of the PFAS compounds are volatilized by the heat and then removed from the soil by vacuum extraction. The vapors must be treated and eventually discharged while meeting local and/or federal standards. Two types of vapor treatment have been used in past TCH applications for organics: (1) thermal and catalytic oxidation and (2) condensation followed by granular activated charcoal (GAC) filtration. Due to uncertainties related to thermal destruction of fluorinated compounds and future requirements for treatment temperature and residence time, condensation and GAC filtration have been used in the first three PFAS treatment field demonstrations. It should be noted that PFAS compounds will stick to surfaces and that decontamination of the equipment is important. This could generate additional waste as GAC vessels, pipes and other wetted equipment need careful cleaning with solvents or rinsing agents such as PerfluorAd<sup><small>TM</small></sup>.  
 
  
−
==PFAS Reactivity and Fate==
+
*Rates of other processes that often limit the pace of remediation, such as dissolution, desorption, and [[Matrix Diffusion | back diffusion]], are positively correlated with temperature. This results in an enhanced bioavailability of contaminant mass that may otherwise be inaccessible.
−
While evaluating initial soil treatment results, Crownover ''et al''<ref name="CrownoverEtAl2019"/> noted the lack of complete data sets when the soils were analyzed for non-targeted compounds or extractable precursors. Attempts to establish the fluorine balance suggest that the final fate of the fluorine in the PFAS is not yet fully understood. Transformations are likely occurring in the heated soil as demonstrated in laboratory experiments with and without calcium hydroxide (Ca(OH)<small><sub>2</sub></small>) amendment<ref>Koster van Groos, P.G., 2021. Small-Scale Thermal Treatment of Investigation-Derived Wastes Containing PFAS. [https://serdp-estcp.mil/ Strategic Environmental Research and Development Program (SERDP) - Environmental Security Technology Certification Program (ESTCP)], [https://serdp-estcp.mil/projects/details/2f1577ac-c8ea-4ae8-804e-c9f97a12edb3/small-scale-thermal-treatment-of-investigation-derived-wastes-idw-containing-pfas Project ER18-1556 Website], [[Media: ER18-1556_Final_Report.pdf | Final Report.pdf]]</ref>. Amendments such as Ca(OH)<sub><small>2</small></sub> may be useful in reducing the required treatment temperature by catalyzing PFAS degradation. With thousands of PFAS potentially present, the interactions are complex and may never be fully understood. Therefore, successful thermal treatment may require a higher target temperature than for other organics with similar boiling points – simply to provide a buffer against the uncertainty.
 
  
−
==Case Studies==
+
These various mechanisms collectively contribute to the improved performance of other active treatments when temperature is moderately increased by utilization of TISR®.
−
===Stockpile Treatment, Eielson AFB, Alaska ([https://serdp-estcp.mil/projects/details/62098505-de86-43b2-bead-ae8018854141 ESTCP project ER20-5198]<ref name="CrownoverEtAl2023">Crownover, E., Heron, G., Pennell, K., Ramsey, B., Rickabaugh, T., Stallings, P., Stauch, L., Woodcock, M., 2023. Ex Situ Thermal Treatment of PFAS-Impacted Soils, [[Media: ER20-5198 Final Report.pdf | Final Report.]] Eielson Air Force Base, Alaska. [https://serdp-estcp.mil/ Strategic Environmental Research and Development Program (SERDP) - Environmental Security Technology Certification Program (ESTCP)], [https://serdp-estcp.mil/projects/details/62098505-de86-43b2-bead-ae8018854141 Project ER20-5198 Website]</ref>)===
 
−
[[File: HeronFig1.png | thumb | 400 px | Figure 1. TCH treatment of a PFAS-laden stockpile at Eielson AFB, Alaska<ref name="CrownoverEtAl2023"/>]]
 
−
Since there has been no approved or widely accepted method for treating soils impacted by PFAS, a common practice has been to excavate PFAS-impacted soil and place it in lined stockpiles. Eielson AFB in Alaska is an example where approximately 50 stockpiles were constructed to temporarily store 150,000 cubic yards of soil. One of the stockpiles containing 134 cubic yards of PFAS-impacted soil was heated to 350-450&deg;C over 90 days (Figure 1). Volatilized PFAS was extracted from the soil using vacuum extraction and treated via condensation and filtration by granular activated charcoal. Under field conditions, PFAS concentration reductions from 230 µg/kg to below 0.5 µg/kg were demonstrated for soils that reached 400&deg;C or higher for 7 days. These soils achieved the Alaska soil standards of 3 µg/kg for PFOS and 1.7 µg/kg for PFOA. Cooler soils near the top of the stockpile had remaining PFOS in the range of 0.5-20 µg/kg with an overall average of 4.1 µg/kg. Sampling of all soils heated to 400&deg;C or higher demonstrated that the soils achieved undetectable levels of targeted PFAS (typical reporting limit was 0.5 µg/kg).
 
  
−
===''In situ'' Vadose Zone Treatment, Beale AFB, California ([https://serdp-estcp.mil/projects/details/94949542-f9f7-419d-8028-8ba318495641/er20-5250-project-overview ESTCP project ER20-5250]<ref name="Iery2024">Iery, R. 2024. In Situ Thermal Treatment of PFAS in the Vadose Zone. [https://serdp-estcp.mil/ Strategic Environmental Research and Development Program (SERDP) - Environmental Security Technology Certification Program (ESTCP)], [https://serdp-estcp.mil/projects/details/94949542-f9f7-419d-8028-8ba318495641 Project ER20-5250 Website]. [[Media: ER20-5250 Fact Sheet.pdf | Fact Sheet.pdf]]</ref>)===
+
==Implementation and Practical Considerations==
−
[[File: HeronFig2.png | thumb | 600 px | Figure 2. ''In situ'' TCH treatment of a PFAS-rich vadose zone hotspot at Beale AFB, California]]
+
[[File: MunhollandFig3.png | thumb | 500 px | Figure 3: Transformation of 1,1-DCE and VC following installation of a TISR<sup>®</sup> system]]
−
A former fire-training area at Beale AFB had PFAS concentrations as high as 1,970 µg/kg in shallow soils. In situ treatment of a PFAS-rich soil was demonstrated using 16 TCH borings installed in the source area to a depth of 18 ft (Figure 2). Soils which reached the target temperatures were reduced to PFAS concentrations below 1 µg/kg. Perched water which entered in one side of the area delayed heating in that area, and soils which were affected had more modest PFAS concentration reductions. As a lesson learned, future in situ TCH treatments will include provisions for minimizing water entering the treated volume<ref name="Iery2024"/>. It was demonstrated that with proper water management, even highly impacted soils can be treated to near non-detect concentrations (greater than 99% reduction).
+
TISR<sup>®</sup> has proven successful in reducing contaminant concentrations across diverse hydrogeologic settings, including those with low and complex hydraulic conductivity conditions. Figure 3 shows a sharp initial decrease in [[Wikipedia: 1,1-Dichloroethylene | 1,1-dichloroethene (1,1-DCE)]] concentrations due to enhanced biodegradation, and then a temporary small increase followed by subsequent decreases in 1,1-DCE concentrations to below detection limits, possibly the result of temperature-enhanced desorption or dissolution of 1,1-DCE from the aquifer. There is also a temporary increase and then decrease in the concentrations of [[Wikipedia: Vinyl chloride | vinyl chloride (VC)]] (a biodegradation product) to very low levels.  
  
−
===Constructed Pile Treatment, JBER, Alaska ([https://serdp-estcp.mil/projects/details/eb7311db-6233-4c7f-b23a-e003ac1926c5/pfas-treatment-in-soil-using-thermal-conduction-heating ESTCP Project ER23-8369]<ref name="CrownoverHeron2024">Crownover, E., Heron, G., 2024. PFAS Treatment in Soil Using Thermal Conduction Heating. Defense Innovation Unit (DIU) and [https://serdp-estcp.mil/ Strategic Environmental Research and Development Program (SERDP) - Environmental Security Technology Certification Program (ESTCP)], [https://serdp-estcp.mil/projects/details/eb7311db-6233-4c7f-b23a-e003ac1926c5/pfas-treatment-in-soil-using-thermal-conduction-heating Project ER23-8369 Website]</ref>)===
+
The TISR<sup>®</sup> system construction utilizes off-the-shelf modular components, promoting cost-efficiency, reusability, and a reduced carbon footprint. Waste heat can supplement or replace the solar setup, and remote monitoring through dashboard apps reduces operation and maintenance costs. TISR® projects typically achieve an average capital cost payback within 1 to 3 years due to accelerated rates of remediation.
−
[[File: HeronFig3.png | thumb | 600 px | Figure 3. Treatment of a 2,000 cubic yard soil pile at JBER, Alaska]]
 
−
In 2024, a stockpile of 2,000 cubic yards of PFAS-impacted soil was thermally treated at Joint Base Elmendorf-Richardson (JBER) in Anchorage, Alaska<ref name="CrownoverHeron2024"/>. This ESTCP project was implemented in partnership with DOD’s Defense Innovation Unit (DIU). Three technology demonstrations were conducted at the site where approximately 6,000 cy of PFAS-impacted soil was treated (TCH, smoldering and kiln-style thermal desorption). Figure 3 shows the fully constructed pile used for the TCH demonstration. In August 2024 the soil temperature for the TCH treatment exceeded 400&deg;C in all monitoring locations. At an energy density of 355 kWh/cy, Alaska Department of Environmental Conservation (ADEC) standards and EPA Residential Regional Screening Levels (RSLs) for PFAS in soil were achieved. At JBER, all 30 post-treatment soil samples were near or below detection limits for all targeted PFAS compounds using EPA Method 1633. The composite of all 30 soil samples was below all detection limits for EPA Method 1633. Detection limits ranged from 0.0052 µg/kg to 0.19 µg/kg.
 
  
−
==Advantages and Disadvantages==
+
When implementing TISR<sup>®</sup>, [[Wikipedia: Solar irradiance | solar insolation]] and groundwater velocity must be considered for optimal equipment sizing and cycling. Depending on remedial goals and site history and conditions, the TISR<sup>®</sup> system and target temperatures may be designed to enhance specific remedial mechanisms (e.g. hydrolysis over bioremediation). Recently Ornelles ''et al.''<ref name="Ornelles"/> developed an easy to use Excel-based model that can be used to optimize TISR<sup>®</sup> design and predict subsurface temperature changes over time. Frequent monitoring of the temperature and microbial community composition relative to targets is useful for evaluating treatment effectiveness and optimizing system performance. The system and target temperatures can be customized to enhance specific remedial mechanisms based on site conditions and goals.  
−
Thermal treatment of PFAS in soils is energy intensive, and the cost of that energy may be prohibitive for some clients. Also, while it often is the least costly option for complete PFAS removal when compared to excavation followed by offsite disposal or destruction, heating soil to treatment temperatures on site or ''in situ'' typically takes longer than excavation. Major advantages include:
 
−
*On site or ''in situ'' treatment eliminates the need to transport and dispose of the contaminated soil
 
−
*Site liabilities are removed once and for all
 
−
*Treatment costs are competitive with excavation, transportation and off-site treatment or disposal.
 
  
−
==Recommendations==
+
==Summary==
−
Recent research suggests:
+
TISR<sup>®</sup> is a cost-effective and adaptable technology that can be customized to address specific site challenges. It can be used as a standalone solution or be integrated with existing remediation strategies to enhance their effectiveness. TISR<sup>®</sup> is particularly effective in challenging hydrogeological conditions and can be optimized to suit specific treatment mechanisms. By shortening the active remediation timeframe, TISR<sup>®</sup> reduces lifecycle costs and minimizes the carbon footprint associated with the remediation process.
−
*Successful thermal treatment of PFAS may require a higher target temperature than for other organics with similar boiling points
+
<br clear="right"/>
−
*Prevention of influx of water into treatment zone may be necessary.
 
−
Future studies should examine the potential for enhanced degradation during the thermal process by using soil amendments and/or manipulation of the local geochemistry to reduce the required treatment temperatures and therefore also reduce energy demand.
 
  
 
==References==
 
==References==
Line 63: Line 63:
  
 
==See Also==
 
==See Also==
 +
[https://vimeo.com/1019489395 TISR<sup>®</sup> Explanation Video]

Latest revision as of 19:44, 13 October 2026

Thermal In Situ Sustainable Remediation to Enhance Biotic and Abiotic Reactions and Accelerate Remediation Timeframes

Thermal In Situ Sustainable Remediation (TISR®; US Pat. Nos. 10,384,246 and 10,688,545) is a cost-effective and adaptable low temperature thermal remediation technology that accelerates contaminant treatment. It achieves this by enhancing biotic and abiotic contaminant degradation rates through a modest increase in subsurface temperature. TISR® is suitable for a wide range of hydrogeologic settings. It also offers reduced operational costs, a lower carbon footprint, and possibly shorter remedial timeframes than more conventional methods.

Related Article(s):

Contributors: Jonah Munholland, Julia Vidonish, and Craig Divine

Key Resources:

  • Thermal In Situ Sustainable Remediation to Enhance Biotic and Abiotic Reactions and Accelerate Remediation Timeframes, Final Report. ESTCP Project ER20-5028[1].
  • Advances in Low-Temperature Thermal Remediation. Munholland et al., 2024[2].
  • A Design Tool for Solar Thermal Remediation Using Borehole Heat Exchangers. Ornelles, Falta, and Divine, 2023[3].
  • Low-Temperature Thermal Remediation: Gaining Traction as a Green Remedial Alternative. Horst, et al., 2018[4].

Introduction

File:MunhollandFig1.png
Figure 1: Components and layout of a TISR® system

TISR® utilizes borehole heat exchangers (BHEs) to heat target treatment areas in the subsurface. This is achieved through a combination of solar collectors, which harness solar radiation as heat, and the utilization of other heat sources such as waste heat or hybrid heating with heat pumps. That heat is then transferred to the subsurface via a closed loop circulation system connected to the BHEs (Figure 1). By incorporating these additional heat sources, TISR® ensures a more robust and constant heat supply, enabling customization of the system to address specific site challenges and facilitate efficient heat transfer.

The heating of the subsurface through TISR® accelerates various processes such as biodegradation, abiotic reactions, and contaminant desorption and dissolution. The technology is also suitable for diverse hydrogeologic environments, including sites with low permeability zones, due to the relatively uniform thermal conductivity of geologic materials, which is unaffected by grain size[2]. This versatility allows TISR® to integrate with conventional remediation technologies, enhancing their performance.

One of the key advantages of TISR® is its ability to accelerate treatment processes while minimizing energy consumption. By harnessing renewable and sustainable energy sources such as solar radiation and effectively utilizing waste heat or hybrid heating with heat pumps, TISR® delivers an efficient, cost-effective remediation solution. Compatibility with multiple conventional remediation technologies makes it an effective option for addressing a variety of contamination challenges.

Scientific Principles

File:MunhollandFig2.png
Figure 2: Effect of temperature on hydrolysis rates for VOCs

During the TISR® heating process, thermal conduction and advection play a crucial role in boosting physical, biological, and chemical processes within the treatment zones, leading to enhanced attenuation, degradation, and removal of contaminants from the subsurface[5][4]. TISR® systems are typically designed to enhance the biological activity and performance of other active technologies, such as air sparge/ soil vapor extraction (AS/SVE) or chemical oxidation, by increasing the subsurface temperature by approximately 10°C to 20°C. The target groundwater temperature is often set to reach up to about 35°C, which is the optimal temperature for promoting the activity of mesophilic microbial communities responsible for biodegradation of certain contaminants. In cases where the objective is to maximize abiotic hydrolysis mechanisms, such as for some chlorinated alkanes, TISR® systems can be designed to reach a final groundwater temperature of up to 60°C.

The effectiveness of TISR® in enhancing treatment performance has been demonstrated through several mechanisms, which are discussed below:

  • Primary dechlorinating bacteria, such as Dehalococcoides and Dehalogenimonas, are known to be mesophilic. Therefore, increasing the temperature can significantly enhance microbial activity and biodegradation by multiple orders of magnitude[6].
  • Reduced iron minerals, particularly iron sulfides, can participate in the abiotic degradation of chlorinated ethenes and other contaminants. The rates of these reactions generally depend on temperature, following the Arrhenius equation.
  • Rates of other processes that often limit the pace of remediation, such as dissolution, desorption, and back diffusion, are positively correlated with temperature. This results in an enhanced bioavailability of contaminant mass that may otherwise be inaccessible.

These various mechanisms collectively contribute to the improved performance of other active treatments when temperature is moderately increased by utilization of TISR®.

Implementation and Practical Considerations

File:MunhollandFig3.png
Figure 3: Transformation of 1,1-DCE and VC following installation of a TISR® system

TISR® has proven successful in reducing contaminant concentrations across diverse hydrogeologic settings, including those with low and complex hydraulic conductivity conditions. Figure 3 shows a sharp initial decrease in 1,1-dichloroethene (1,1-DCE) concentrations due to enhanced biodegradation, and then a temporary small increase followed by subsequent decreases in 1,1-DCE concentrations to below detection limits, possibly the result of temperature-enhanced desorption or dissolution of 1,1-DCE from the aquifer. There is also a temporary increase and then decrease in the concentrations of vinyl chloride (VC) (a biodegradation product) to very low levels.

The TISR® system construction utilizes off-the-shelf modular components, promoting cost-efficiency, reusability, and a reduced carbon footprint. Waste heat can supplement or replace the solar setup, and remote monitoring through dashboard apps reduces operation and maintenance costs. TISR® projects typically achieve an average capital cost payback within 1 to 3 years due to accelerated rates of remediation.

When implementing TISR®, solar insolation and groundwater velocity must be considered for optimal equipment sizing and cycling. Depending on remedial goals and site history and conditions, the TISR® system and target temperatures may be designed to enhance specific remedial mechanisms (e.g. hydrolysis over bioremediation). Recently Ornelles et al.[3] developed an easy to use Excel-based model that can be used to optimize TISR® design and predict subsurface temperature changes over time. Frequent monitoring of the temperature and microbial community composition relative to targets is useful for evaluating treatment effectiveness and optimizing system performance. The system and target temperatures can be customized to enhance specific remedial mechanisms based on site conditions and goals.

Summary

TISR® is a cost-effective and adaptable technology that can be customized to address specific site challenges. It can be used as a standalone solution or be integrated with existing remediation strategies to enhance their effectiveness. TISR® is particularly effective in challenging hydrogeological conditions and can be optimized to suit specific treatment mechanisms. By shortening the active remediation timeframe, TISR® reduces lifecycle costs and minimizes the carbon footprint associated with the remediation process.

References

  1. ^ Divine, C., Munholland, J., Zardouzian, E., Justicia-Leon, S., Aspinall, J.V., Randhawa, D., Falta, R., Freedman, D., Becker, M., 2025. Thermal In Situ Sustainable Remediation to Enhance Biotic and Abiotic Reactions and Accelerate Remediation Timeframes, Final Report. Environmental Security Technology Certification Program (ESTCP), Project ER20-5028. Project Website  Final Report.pdf
  2. ^ 2.0 2.1 Munholland, J, Rosso, D., Randhawa, D., Devine, C., Pennington, A., 2024. Advances in Low-Temperature Thermal Remediation. In: García-Rincón, J., Gatsios, E., Lenhard, R.J., Atekwana, E.A., Naidu, R. (eds), Advances in the Characterisation and Remediation of Sites Contaminated with Petroleum Hydrocarbons, Chapter 18 pp. 623-653. Environmental Contamination Remediation and Management series, Springer Nature. doi: 10.1007/978-3-031-34447-3_18  Open Access Chapter
  3. ^ 3.0 3.1 Ornelles, A.D., Falta, R.W., Divine, C.E., 2023. A Design Tool for Solar Thermal Remediation Using Borehole Heat Exchangers. Ground Water, 61(2), pp. 245-254. doi: 10.1111/gwat.13265  Free download from NGWA
  4. ^ 4.0 4.1 Horst, J., Flanders, C., Klemmer, M., Randhawa, D.S., Rosso, D., 2018. Low-Temperature Thermal Remediation: Gaining Traction as a Green Remedial Alternative. Groundwater Monitoring and Remediation, 38(3), pp. 18-27. doi: 10.1111/gwmr.12295
  5. ^ Dettmer, K., 2002. A Discussion of the Effects of Thermal Remediation Treatments on Microbial Degradation Processes. U.S. Environmental Protection Agency, Office of Solid Waste and Emergency Response, Technology Innovation Office, Washington, DC. free report  free download from clu-in.org
  6. ^ Macbeth, T., Truex, M., Powell, T., Michalsen, M., 2012. Combining Low-Energy Electrical Resistance Heating with Biotic and Abiotic Reactions for Treatment of Chlorinated Solvent DNAPL Source Areas. Environmental Security Technology Certification Program (ESTCP) Project ER-200719 webpage  free download  Project Summary Presentation
  7. ^ Suthersan, S., Horst, J., Klemmer, M., Malone, D., 2012. Temperature-Activated Auto-Decomposition Reactions: An Under-Utilized In Situ Remediation Solution. Groundwater Monitoring and Remediation, 32(3), pp. 34-40. doi: 10.1111/j.1745-6592.2012.01407.x
  8. ^ Chen, F., Freedman, D.L., Falta, R.W., Murdoch, L.C., 2012. Henry's law constants of chlorinated solvents at elevated temperatures. Chemosphere, 86(2), pp.156-165. doi: 10.1016/j.chemosphere.2011.10.004

See Also

TISR® Explanation Video