==PFAS Sources==
+
==Thermal In Situ Sustainable Remediation to Enhance Biotic and Abiotic Reactions and Accelerate Remediation Timeframes==  
−
[[Perfluoroalkyl and Polyfluoroalkyl Substances (PFAS)]] have been used in coatings for textiles, paper products, and cookware; in some firefighting foams; and have a range of applications in the aerospace, photographic imaging, semiconductor, automotive, construction, electronics, and aviation industries<ref name="ITRC2020">Interstate Technology and Regulatory Council (ITRC), 2020. Technical/Regulatory Guidance: Per- and Polyfluoroalkyl Substances (PFAS), PFAS-1. ITRC, PFAS Team, Washington DC. Website:  https://pfas-1.itrcweb.org/ &nbsp;&nbsp; [https://pfas-1.itrcweb.org/wp-content/uploads/2020/04/ITRC_PFAS_TechReg_April2020.pdf  Free Download from ITRC].&nbsp;&nbsp; [[Media: ITRC_PFAS-1.pdf | Report.pdf]]</ref><ref name="KEMI2015">Swedish Chemicals Agency (KEMI), 2015. Occurrence and use of highly fluorinated substances and alternatives, Report 7/15. ISSN 0284-1185. Article number 361 164.  [[Media: KEMI2015.pdf | Report.pdf]]</ref><ref name="USEPA2021">US Environmental Protection Agency (USEPA), 2021. Basic Information on PFAS.  [https://www.epa.gov/pfas/basic-information-pfas#tab-1 Website]</ref>. Although PFAS and PFAS-containing products have been manufactured since the 1950s, PFAS were not widely documented in environmental samples until the early 2000s. Understanding PFAS manufacturing history, past and current uses, and waste management over the last six to seven decades is necessary for the identification of potential environmental sources of PFAS, possible release mechanisms, and associated pathway-receptor relationships.
+
Thermal In Situ Sustainable Remediation (TISR<sup>®</sup>; US Pat. Nos. 10,384,246 and 10,688,545) is a cost-effective and adaptable low temperature thermal remediation technology that accelerates contaminant treatment. It achieves this by enhancing biotic and abiotic contaminant degradation rates through a modest increase in subsurface temperature. TISR<sup>®</sup> is suitable for a wide range of hydrogeologic settings. It also offers reduced operational costs, a lower carbon footprint, and possibly shorter remedial timeframes than more conventional methods.
 
<div style="float:right;margin:0 0 2em 2em;">__TOC__</div>
 
<div style="float:right;margin:0 0 2em 2em;">__TOC__</div>
  
 
'''Related Article(s):'''
 
'''Related Article(s):'''
  
−
* [[Perfluoroalkyl and Polyfluoroalkyl Substances (PFAS)]]
+
*[[Thermal Remediation]]
−
* [[PFAS Transport and Fate]]
+
*[[Thermal Remediation - Electrical Resistance Heating | Electrical Resistance Heating]]
 +
*[[Thermal Conduction Heating (TCH)]]
 +
*[[Thermal Remediation - Combined Remedies | Combined Remedies]]
  
−
'''Contributor(s):''' [[Dr. Sheau-Yun (Dora) Chiang]] and [[Dr. Alexandra Salter-Blanc]]
+
'''Contributors:''' Jonah Munholland, Julia Vidonish, and Craig Divine
  
−
'''Key Resource(s):'''
+
'''Key Resources:'''
 +
*Thermal In Situ Sustainable Remediation to Enhance Biotic and Abiotic Reactions and Accelerate Remediation Timeframes, Final Report. ESTCP Project ER20-5028<ref>Divine, C., Munholland, J., Zardouzian, E., Justicia-Leon, S., Aspinall, J.V., Randhawa, D., Falta, R., Freedman, D., Becker, M., 2025. Thermal In Situ Sustainable Remediation to Enhance Biotic and Abiotic Reactions and Accelerate Remediation Timeframes, Final Report. Environmental Security Technology Certification Program (ESTCP), Project ER20-5028. [https://serdp-estcp.mil/projects/details/bab4bc87-b4bc-42df-ad0e-11ea0adf27dc/er20-5028-project-overview Project Website]&nbsp; [[Media: ER20-5028 FR DevineEtAl2025.pdf | Final Report.pdf]]</ref>.
  
−
*[https://pfas-1.itrcweb.org/wp-content/uploads/2020/04/ITRC_PFAS_TechReg_April2020.pdf  Per- and Polyfluoroalkyl Substances (PFAS), PFAS-1. ITRC 2020.]<ref name="ITRC2020"/>
+
*Advances in Low-Temperature Thermal Remediation. Munholland ''et al.'', 2024<ref name="MunhollandEtAl2024">Munholland, J, Rosso, D., Randhawa, D., Devine, C., Pennington, A., 2024. Advances in Low-Temperature Thermal Remediation. In: García-Rincón, J., Gatsios, E., Lenhard, R.J., Atekwana, E.A., Naidu, R. (eds), Advances in the Characterisation and Remediation of Sites Contaminated with Petroleum Hydrocarbons, Chapter 18 pp. 623-653. Environmental Contamination Remediation and Management series, Springer Nature. [https://doi.org/10.1007/978-3-031-34447-3_18 doi: 10.1007/978-3-031-34447-3_18]&nbsp; [[Media: MunhollandEtAl2024.pdf | Open Access Chapter]]</ref>.
  
−
==Introduction==
+
*A Design Tool for Solar Thermal Remediation Using Borehole Heat Exchangers. Ornelles, Falta, and Divine, 2023<ref name="Ornelles">Ornelles, A.D., Falta, R.W., Divine, C.E., 2023. A Design Tool for Solar Thermal Remediation Using Borehole Heat Exchangers. Ground Water, 61(2), pp. 245-254. [https://doi.org/10.1111/gwat.13265 doi: 10.1111/gwat.13265]&nbsp; [https://ngwa.onlinelibrary.wiley.com/doi/epdf/10.1111/gwat.13265 Free download from NGWA]</ref>.  
−
[[Perfluoroalkyl and Polyfluoroalkyl Substances (PFAS)]] are a complex family of more than 3,000 manmade fluorinated organic chemicals<ref name="Wang2017">Wang, Z., DeWitt, J.C., Higgins, C.P., and Cousins, I.T., 2017. A Never-Ending Story of Per- and Poly-Fluoroalkyl Substances (PFASs)? Environmental Science and Technology, 51(5), pp. 2508-2518.  [https://doi.org/10.1021/acs.est.6b04806 DOI: 10.1021/acs.est.6b04806]&nbsp;&nbsp; [[Media: Wang2017.pdf | Open access article.]]</ref> although not all of these are currently in use or production. PFAS are produced using several different processes. Fluorosurfactants, which include perfluoroalkyl acids (PFAAs) (see [[Perfluoroalkyl and Polyfluoroalkyl Substances (PFAS) | PFAS]] article for nomenclature) and side-chain fluorinated polymers, have been manufactured using two major processes: [[Wikipedia: Electrochemical fluorination | electrochemical fluorination (ECF)]] and [[Wikipedia: Telomerization | telomerization]]<ref name="KEMI2015"/>. ECF was licensed by 3M in the 1940s<ref name="Banks1994">Banks, R.E., Smart, B.E. and Tatlow, J.C. eds., 1994. Organofluorine Chemistry: Principles and Commercial Applications. Springer Science and Business Media, New York, N. Y. [https://link.springer.com/book/10.1007/978-1-4899-1202-2 DOI: 10.1007/978-1-4899-1202-2]</ref> and used by 3M until 2001. ECF produces a mixture of even and odd numbered carbon chain lengths of approximately 70% linear and 30% branched substances<ref name="Concawe2016">Concawe (Conservation of Clean Air and Water in Europe), 2016.  Environmental fate and effects of poly- and perfluoroalkyl substances (PFAS).  Report No. 8/16. Brussels, Belgium. [[Media:Concawe2016.pdf | Report.pdf]]</ref>. Telomerization was developed in the 1970s<ref name="Benskin2012a">Benskin, J.P., Ahrens, L., Muir, D.C., Scott, B.F., Spencer, C., Rosenberg, B., Tomy, G., Kylin, H., Lohmann, R. and Martin, J.W., 2012. Manufacturing Origin of Perfluorooctanoate (PFOA) in Atlantic and Canadian Arctic Seawater. Environmental Science and Technology, 46(2), pp. 677-685. [https://doi.org/10.1021/es202958p DOI: 10.1021/es202958p]</ref>, and yields mainly even numbered, straight carbon chain isomers<ref name="Kissa2001">Kissa, E., 2001. Fluorinated Surfactants and Repellents, Second Edition. Surfactant Science Series, Vol. 97. Marcel Dekker, Inc., CRC Press, New York. 640 pages. ISBN: 9780824704728</ref><ref name="Parsons2008">Parsons, J.R., Sáez, M., Dolfing, J. and De Voogt, P., 2008. Biodegradation of Perfluorinated Compounds. Reviews of Environmental Contamination and Toxicology, 196, pp. 53-71. Springer, New York, NY.  [https://doi.org/10.1007/978-0-387-78444-1_2 DOI: 10.1007/978-0-387-78444-1_2]&nbsp;&nbsp; Free download from: [https://www.researchgate.net/profile/Jan_Dolfing/publication/23489065_Biodegradation_of_Perfluorinated_Compounds/links/0912f5087a40c9d5df000000.pdf ResearchGate]</ref>.  PFAS manufacturers have provided PFAS to secondary manufacturers for production of a vast array of industrial and consumer products.  
 
  
−
During manufacturing, PFAS may be released into the atmosphere then redeposited on land where they can also affect surface water and groundwater, or PFAS may be discharged without treatment to wastewater treatment plants or landfills, and eventually be released into the environment by treatment systems that are not designed to mitigate PFAS (see also [[PFAS Transport and Fate]]). Industrial discharges of PFAS were unregulated for many years, but that has begun to change. In January 2016, New York became the first state in the nation to regulate PFOA as a hazardous substance followed by the regulation of PFOS in April 2016. Consumer and industrial uses of PFAS-containing products can also end up releasing PFAS into landfills and into municipal wastewater, where it may accumulate undetected in biosolids which are typically treated by land application.  
+
*Low-Temperature Thermal Remediation: Gaining Traction as a Green Remedial Alternative. Horst, ''et al.'', 2018<ref name="HorstEtAl2018">Horst, J., Flanders, C., Klemmer, M., Randhawa, D.S., Rosso, D., 2018. Low-Temperature Thermal Remediation: Gaining Traction as a Green Remedial Alternative. Groundwater Monitoring and Remediation, 38(3), pp. 18-27. [https://doi.org/10.1111/gwmr.12295 doi: 10.1111/gwmr.12295]</ref>.
  
−
==Industrial Sources==  
+
==Introduction==
−
PFAS are used in many industrial and consumer applications, which may have released PFAS into the environment and impacted drinking water supplies in many areas of the United States<ref name="EWG2017">Environmental Working Group (EWG) and Northeastern University Social Science Environmental Health Research Institute, 2017. Mapping A Contamination Crisis. [https://www.ewg.org/research/mapping-contamination-crisis Website]</ref>. Both in the United States (US) and abroad, primary manufacturing facilities produce PFAS and secondary manufacturing facilities use PFAS to produce goods. Environmental release mechanisms associated with these facilities include air emission and dispersion, spills, and disposal of manufacturing wastes and wastewater. Potential impacts to air, soil, sediment, surface water, stormwater, and groundwater are present not only at primary release points but potentially over the surrounding area<ref name="Shin2011">Shin, H.M., Vieira, V.M., Ryan, P.B., Detwiler, R., Sanders, B., Steenland, K., and Bartell, S.M., 2011. Environmental Fate and Transport Modeling for Perfluorooctanoic Acid Emitted from the Washington Works Facility in West Virginia. Environmental Science and Technology, 45(4), pp. 1435-1442.  [https://doi.org/10.1021/es102769t DOI: 10.1021/es102769t]</ref>. Some of the potential primary and secondary sources of PFAS releases to the environment are listed here<ref name="ITRC2020"/>:
+
[[File: MunhollandFig1.png | thumb | 500 px | Figure 1: Components and layout of a TISR<sup>®</sup> system]]
 +
TISR<sup>®</sup> utilizes [[Wikipedia: Downhole heat exchanger | borehole heat exchangers (BHEs)]] to heat target treatment areas in the subsurface. This is achieved through a combination of solar collectors, which harness solar radiation as heat, and the utilization of other heat sources such as waste heat or hybrid heating with heat pumps. That heat is then transferred to the subsurface via a closed loop circulation system connected to the BHEs (Figure 1). By incorporating these additional heat sources, TISR<sup>®</sup> ensures a more robust and constant heat supply, enabling customization of the system to address specific site challenges and facilitate efficient heat transfer.
  
−
* '''Textiles and leather:''' Factory or consumer applied coating to repel water, oil, and stains. Applications include protective clothing and outerwear, umbrellas, tents, sails, architectural materials, carpets, and upholstery<ref name="Rao1994">Rao, N.S., and Baker, B.E., 1994. Textile Finishes and Fluorosurfactants. In: Organofluorine Chemistry, Banks, R.E., Smart, B.E., and Tatlow, J.C., Eds. Springer, New York.  [https://doi.org/10.1007/978-1-4899-1202-2_15 DOI: 10.1007/978-1-4899-1202-2_15]</ref><ref name="Hekster2003">Hekster, F.M., Laane, R.W. and De Voogt, P., 2003. Environmental and Toxicity Effects of Perfluoroalkylated Substances. Reviews of Environmental Contamination and Toxicology, 179, pp. 99-121. Springer, New York, NY. [https://doi.org/10.1007/0-387-21731-2_4 DOI: 10.1007/0-387-21731-2_4]</ref><ref name="Brooke2004">Brooke, D., Footitt, A., and Nwaogu, T.A., 2004. Environmental Risk Evaluation Report: Perfluorooctanesulphonate (PFOS).  Environment Agency (UK), Science Group.  Free download from: [http://chm.pops.int/Portals/0/docs/from_old_website/documents/meetings/poprc/submissions/Comments_2006/sia/pfos.uk.risk.eval.report.2004.pdf The Stockholm Convention]&nbsp;&nbsp; [[Media:Brooke2004.pdf | Report.pdf]]</ref><ref name="Poulsen2005">Poulsen, P.B., Jensen, A.A., and Wallström, E., 2005. More environmentally friendly alternatives to PFOS-compounds and PFOA. Danish Environmental Protection Agency, Environmental Project 1013.  [[Media: Poulsen2005.pdf | Report.pdf]]</ref><ref name="Prevedouros2006">Prevedouros, K., Cousins, I.T., Buck, R.C. and Korzeniowski, S.H., 2006. Sources, Fate and Transport of Perfluorocarboxylates. Environmental Science and Technology, 40(1), pp. 32-44.  [https://doi.org/10.1021/es0512475 DOI: 10.1021/es0512475]&nbsp;&nbsp; Free download from: [https://www.academia.edu/download/39945519/Sources_Fate_and_Transport_of_Perfluoroc20151112-1647-19vcvbf.pdf Academia.edu]</ref><ref name="Walters2006">Walters, A., and Santillo, D., 2006. Technical Note 06/2006: Uses of Perfluorinated Substances. Greenpeace Research Laboratories. [http://www.greenpeace.to/publications/uses-of-perfluorinated-chemicals.pdf Website]&nbsp;&nbsp; [[Media: Walters2006.pdf | Report.pdf]]</ref><ref name="Trudel2008">Trudel, D., Horowitz, L., Wormuth, M., Scheringer, M., Cousins, I.T. and Hungerbühler, K., 2008. Estimating Consumer Exposure to PFOS and PFOA. Risk Analysis: An International Journal, 28(2), pp. 251-269.  [https://doi.org/10.1111/j.1539-6924.2008.01017.x DOI: 10.1111/j.1539-6924.2008.01017.x]</ref><ref name="Guo2009">Guo, Z., Liu, X., Krebs, K.A. and Roache, N.F., 2009. Perfluorocarboxylic Acid Content in 116 Articles of Commerce, EPA/600/R-09/033. National Risk Management Research Laboratory, US Environmental Protection Agency, Washington, DC.  Available from: [https://cfpub.epa.gov/si/si_public_record_report.cfm?Lab=NRMRL&dirEntryId=206124 US EPA.]&nbsp;&nbsp; [[Media: Guo2009.pdf | Report.pdf]]</ref><ref name="USEPA2009">US Environmental Protection Agency (USEPA), 2009. Long-Chain Perfluorinated Chemicals (PFCs), Action Plan.  [https://www.epa.gov/sites/production/files/2016-01/documents/pfcs_action_plan1230_09.pdf Website]&nbsp;&nbsp; [[Media: USEPA2009.pdf | Report.pdf]]</ref><ref name="Ahrens2011a">Ahrens, L., 2011. Polyfluoroalkyl compounds in the aquatic environment: a review of their occurrence and fate. Journal of Environmental Monitoring, 13(1), pp.20-31.
+
The heating of the subsurface through TISR<sup>®</sup> accelerates various processes such as biodegradation, abiotic reactions, and contaminant desorption and dissolution. The technology is also suitable for diverse hydrogeologic environments, including sites with low permeability zones, due to the relatively uniform thermal conductivity of geologic materials, which is unaffected by grain size<ref name="MunhollandEtAl2024"/>. This versatility allows TISR<sup>®</sup> to integrate with conventional remediation technologies, enhancing their performance.
−
[http://dx.doi.org/10.1039/C0EM00373E DOI: 10.1039/C0EM00373E]. Free download available from: [https://www.researchgate.net/profile/Lutz_Ahrens/publication/47622154_Polyfluoroalkyl_compounds_in_the_aquatic_environment_A_review_of_their_occurrence_and_fate/links/00b7d53762cfedaf12000000/Polyfluoroalkyl-compounds-in-the-aquatic-environment-A-review-of-their-occurrence-and-fate.pdf ResearchGate]</ref><ref name="Buck2011">Buck, R.C., Franklin, J., Berger, U., Conder, J.M., Cousins, I.T., De Voogt, P., Jensen, A.A., Kannan, K., Mabury, S.A. and van Leeuwen, S.P., 2011. Perfluoroalkyl and Polyfluoroalkyl Substances in the Environment: Terminology, Classification, and Origins. Integrated Environmental Assessment and Management, 7(4), pp. 513-541. [https://doi.org/10.1002/ieam.258 DOI: 10.1002/ieam.258]&nbsp;&nbsp; [[Media:Buck2011.pdf | Open access article.]]</ref><ref name="UNEP2011">United Nations Environmental Programme (UNEP), 2011. Report of the persistent organic pollutants review committee on the work of its sixth meeting, Addendum, Guidance on alternatives to perfluorooctane sulfonic acid and its derivatives, UNEP/POPS/POPRC.6/13/Add.3/Rev.1 [http://www.pops.int/TheConvention/POPsReviewCommittee/Meetings/POPRC6/POPRC6Documents/tabid/783/ctl/Download/mid/3507/Default.aspx?id=125 Website]&nbsp;&nbsp; [[Media: UNEP2011.pdf | Report.pdf]]</ref><ref name="Herzke2012">Herzke, D., Olsson, E. and Posner, S., 2012. Perfluoroalkyl and polyfluoroalkyl substances (PFASs) in consumer products in Norway – A pilot study. Chemosphere, 88(8), pp. 980-987.  [https://doi.org/10.1016/j.chemosphere.2012.03.035 DOI: 10.1016/j.chemosphere.2012.03.035]</ref><ref name="Patagonia2016">Patagonia, Inc., 2016. An Update on Our DWR Problem.  [https://www.patagonia.com/stories/our-dwr-problem-updated/story-17673.html Website]&nbsp;&nbsp; [[Media: Patagonia2016.pdf | Report.pdf]]</ref><ref name="Kotthoff2015">Kotthoff, M., Müller, J., Jürling, H., Schlummer, M., and Fiedler, D., 2015. Perfluoroalkyl and polyfluoroalkyl substances in consumer products. Environmental Science and Pollution Research, 22(19), pp. 14546-14559.  [https://doi.org/10.1007/s11356-015-4202-7 DOI: 10.1007/s11356-015-4202-7]&nbsp;&nbsp; [[Media: Kotthoff2015.pdf | Open access article.]]</ref><ref name="ATSDR2018">Agency for Toxic Substances and Disease Registry (ATSDR), 2018. Toxicological Profile for Perfluoroalkyls, Draft for Public Comment. US Department of Health and Human Services. Free download from: [http://www.atsdr.cdc.gov/toxprofiles/tp200.pdf ATSDR]&nbsp;&nbsp; [[Media: ATSDR2018.pdf | Report.pdf]]</ref>.
 
  
−
* '''Paper products:''' Surface coatings to repel grease and moisture. Uses include non-food paper packaging (for example, cardboard, carbonless forms, masking papers) and food-contact materials (for example, pizza boxes, fast food wrappers, microwave popcorn bags, baking papers, pet food bags)<ref name="Rao1994"/><ref name="Kissa2001"/><ref name="Hekster2003"/><ref name="Poulsen2005"/><ref name="Trudel2008"/><ref name="Buck2011"/><ref name="UNEP2011"/><ref name="Kotthoff2015"/><ref name="Schaider2017">Schaider, L.A., Balan, S.A., Blum, A., Andrews, D.Q., Strynar, M.J., Dickinson, M.E., Lunderberg, D.M., Lang, J.R., and Peaslee, G.F., 2017. Fluorinated Compounds in US Fast Food Packaging. Environmental Science and Technology Letters, 4(3), pp. 105-111. [https://doi.org/10.1021/acs.estlett.6b00435 DOI: 10.1021/acs.estlett.6b00435]&nbsp;&nbsp; [[Media: Schaider2017.pdf | Open access article.]]</ref>
+
One of the key advantages of TISR<sup>®</sup> is its ability to accelerate treatment processes while minimizing energy consumption. By harnessing renewable and sustainable energy sources such as solar radiation and effectively utilizing waste heat or hybrid heating with heat pumps, TISR<sup>®</sup> delivers an efficient, cost-effective remediation solution. Compatibility with multiple conventional remediation technologies makes it an effective option for addressing a variety of contamination challenges.
  
−
* '''Metal Plating & Etching:''' Corrosion prevention, mechanical wear reduction, aesthetic enhancement, surfactant, wetting agent/fume suppressant for chrome, copper, nickel and tin electroplating, and post-plating cleaner
+
==Scientific Principles==
 +
[[File: MunhollandFig2.png | thumb | 500 px | Figure 2: Effect of temperature on hydrolysis rates for VOCs]]
 +
During the TISR<sup>®</sup> heating process, thermal conduction and advection play a crucial role in boosting physical, biological, and chemical processes within the treatment zones, leading to enhanced attenuation, degradation, and removal of contaminants from the subsurface<ref>Dettmer, K., 2002. A Discussion of the Effects of Thermal Remediation Treatments on Microbial Degradation Processes. U.S. Environmental Protection Agency, Office of Solid Waste and Emergency Response, Technology Innovation Office, Washington, DC. [[Media: dettmer2002.pdf | free report]]&nbsp; [https://www.clu-in.org/download/techdrct/dettmer.pdf free download from clu-in.org]</ref><ref name="HorstEtAl2018"/>. TISR<sup>®</sup> systems are typically designed to enhance the biological activity and performance of other active technologies, such as [[Wikipedia: Air sparging | air sparge]]/[[Soil Vapor Extraction (SVE) | soil vapor extraction]] (AS/SVE) or [[Chemical Oxidation (In Situ - ISCO) | chemical oxidation]], by increasing the subsurface temperature by approximately 10°C to 20°C. The target groundwater temperature is often set to reach up to about 35°C, which is the optimal temperature for promoting the activity of mesophilic microbial communities responsible for biodegradation of certain contaminants. In cases where the objective is to maximize abiotic hydrolysis mechanisms, such as for some chlorinated alkanes, TISR<sup>®</sup> systems can be designed to reach a final groundwater temperature of up to 60°C.
  
 +
The effectiveness of TISR<sup>®</sup> in enhancing treatment performance has been demonstrated through several mechanisms, which are discussed below:
  
 +
*Primary dechlorinating bacteria, such as [[Wikipedia: Dehalococcoides | Dehalococcoides]] and [[Wikipedia: Dehalogenimonas | Dehalogenimonas]], are known to be [[Wikipedia: Mesophile | mesophilic]]. Therefore, increasing the temperature can significantly enhance microbial activity and biodegradation by multiple orders of magnitude<ref>Macbeth, T., Truex, M., Powell, T., Michalsen, M., 2012. Combining Low-Energy Electrical Resistance Heating with Biotic and Abiotic Reactions for Treatment of Chlorinated Solvent DNAPL Source Areas. [https://serdp-estcp.mil/ Environmental Security Technology Certification Program (ESTCP)] [https://serdp-estcp.mil/projects/details/877a3b41-6bed-4f4a-b43a-87fbcd9b7f0b/er-200719-project-overview Project ER-200719 webpage]&nbsp; [[Media: Macbeth2012_ER-200719-FR.pdf | free download]]&nbsp; [https://www.youtube.com/watch?v=-EbwKbs8scE Project Summary Presentation]</ref>.
  
 +
*Reduced iron minerals, particularly iron sulfides, can participate in the abiotic degradation of chlorinated ethenes and other contaminants. The rates of these reactions generally depend on temperature, following the [[Wikipedia: Arrhenius equation | Arrhenius equation]].
  
 +
*[[Wikipedia: Hydrolysis | Hydrolysis]] rates for certain compounds exhibit high temperature dependence. For example, a 10°C increase can lead to a 50% reduction in the half-life of [[Wikipedia: 1,1,1-Trichloroethane | 1,1,1-trichloroethane (1,1,1-TCA)]]<ref>Suthersan, S., Horst, J., Klemmer, M., Malone, D., 2012. Temperature-Activated Auto-Decomposition Reactions: An Under-Utilized In Situ Remediation Solution. Groundwater Monitoring and Remediation, 32(3), pp. 34-40. [https://doi.org/10.1111/j.1745-6592.2012.01407.x doi: 10.1111/j.1745-6592.2012.01407.x]</ref>. Figure 2 presents the calculated temperature-dependent hydrolysis rates for 13 common [[Wikipedia: Volatile organic compound | volatile organic compounds (VOCs)]] at a pH of 7.
  
 +
*[[Wikipedia: Henry's law | Henry's Law]] constant, [[Wikipedia: Vapor pressure | vapor pressure]], solubility, and viscosity values are also temperature dependent. For instance, the Henry's Law constant values for many VOCs, including [[Wikipedia: Tetrachloroethylene | tetrachloroethene (PCE)]], have been observed to double between 8 and 24°C<ref>Chen, F., Freedman, D.L., Falta, R.W., Murdoch, L.C., 2012. Henry's law constants of chlorinated solvents at elevated temperatures. Chemosphere, 86(2), pp.156-165. [https://doi.org/10.1016/j.chemosphere.2011.10.004 doi: 10.1016/j.chemosphere.2011.10.004]</ref>.
  
−
+
*Rates of other processes that often limit the pace of remediation, such as dissolution, desorption, and [[Matrix Diffusion | back diffusion]], are positively correlated with temperature. This results in an enhanced bioavailability of contaminant mass that may otherwise be inaccessible.
−
[[File:NewellMatrixDiffFig1.PNG | thumb |500px| Figure 1.  Diffusion of a dissolved solute (chlorinated solvent) into lower ''K'' zones during loading period, followed by diffusion back out into higher ''K'' zones once the source is removed <ref name="Sale2007">Sale, T.C., Illangasekare, T.H., Zimbron, J., Rodriguez, D., Wilking, B., and Marinelli, F., 2007. AFCEE Source Zone Initiative. Air Force Center for Environmental Excellence, Brooks City-Base, San Antonio, TX. [https://www.enviro.wiki/images/0/08/AFCEE-2007-Sale.pdf Report.pdf]</ref>]]
 
  
 +
These various mechanisms collectively contribute to the improved performance of other active treatments when temperature is moderately increased by utilization of TISR®.
  
−
[[File: GreenTank.mp4 | thumb |500px| Figure 2. Video of dye tank simulation of matrix diffusion]]
+
==Implementation and Practical Considerations==
−
In some cases, matrix diffusion can maintain contaminant concentrations in more permeable zones above target cleanup goals for decades or potentially even centuries after the primary sources have been addressed. At a site impacted by [[Wikipedia: Dense non-aqueous phase liquid | Dense Non-Aqueous Phase Liquids (DNAPL)]], [[Chlorinated Solvents | trichloroethene (TCE)]] concentrations in downgradient wells declined by roughly an order-of-magnitude (OoM) when the upgradient source area was isolated with sheet piling. However, after this initial decline, TCE concentrations appeared to plateau or decline more slowly, consistent with back diffusion from an underlying aquitard. Numerical simulations indicated that back diffusion would cause TCE concentrations in downgradient wells at the site to remain above target cleanup levels for centuries<ref name="Chapman2005"/>.  
+
[[File: MunhollandFig3.png | thumb | 500 px | Figure 3: Transformation of 1,1-DCE and VC following installation of a TISR<sup>®</sup> system]]
 +
TISR<sup>®</sup> has proven successful in reducing contaminant concentrations across diverse hydrogeologic settings, including those with low and complex hydraulic conductivity conditions. Figure 3 shows a sharp initial decrease in [[Wikipedia: 1,1-Dichloroethylene | 1,1-dichloroethene (1,1-DCE)]] concentrations due to enhanced biodegradation, and then a temporary small increase followed by subsequent decreases in 1,1-DCE concentrations to below detection limits, possibly the result of temperature-enhanced desorption or dissolution of 1,1-DCE from the aquifer. There is also a temporary increase and then decrease in the concentrations of [[Wikipedia: Vinyl chloride | vinyl chloride (VC)]] (a biodegradation product) to very low levels.  
  
−
One other implication of matrix diffusion is that plume migration is attenuated by the loss of contaminants into low permeability zones, leading to slower plume migration compared to a case where no matrix diffusion occurs.  This phenomena was observed as far back as 1985 when Sudicky et al. observed that “A second consequence of the solute-storage effect offered by transverse diffusion into low-permeability layers is a rate of migration of the frontal portion of a contaminant in the permeable layers that is less than the groundwater velocity.”<ref name="Sudicky1985"> Sudicky, E.A., Gillham, R.W., and Frind, E.O., 1985. Experimental Investigation of Solute Transport in Stratified Porous Media: 1. The Nonreactive Case. Water Resources Research, 21(7), pp. 1035-1041. [https://doi.org/10.1029/WR021i007p01035 DOI: 10.1029/WR021i007p01035]</ref>  In cases where there is an attenuating source, matrix diffusion can also reduce the peak concentrations observed in downgradient monitoring wells.  The attenuation caused by matrix diffusion may be particularly important for implementing [[Monitored Natural Attenuation (MNA)]] for contaminants that do not completely degrade, such as [[Metal and Metalloid Contaminants | heavy metals]] and [[Perfluoroalkyl and Polyfluoroalkyl Substances (PFAS)]].
+
The TISR<sup>®</sup> system construction utilizes off-the-shelf modular components, promoting cost-efficiency, reusability, and a reduced carbon footprint. Waste heat can supplement or replace the solar setup, and remote monitoring through dashboard apps reduces operation and maintenance costs. TISR® projects typically achieve an average capital cost payback within 1 to 3 years due to accelerated rates of remediation.
  
−
==SERPD/ESTCP Research==
+
When implementing TISR<sup>®</sup>, [[Wikipedia: Solar irradiance | solar insolation]] and groundwater velocity must be considered for optimal equipment sizing and cycling. Depending on remedial goals and site history and conditions, the TISR<sup>®</sup> system and target temperatures may be designed to enhance specific remedial mechanisms (e.g. hydrolysis over bioremediation). Recently Ornelles ''et al.''<ref name="Ornelles"/> developed an easy to use Excel-based model that can be used to optimize TISR<sup>®</sup> design and predict subsurface temperature changes over time. Frequent monitoring of the temperature and microbial community composition relative to targets is useful for evaluating treatment effectiveness and optimizing system performance. The system and target temperatures can be customized to enhance specific remedial mechanisms based on site conditions and goals.  
−
{|
 
−
The SERDP/ESTCP programs have funded several projects focusing on how matrix diffusion can impede progress towards reaching site closure, including:
 
−
|-
 
−
|
 
−
*[https://www.serdp-estcp.org/Program-Areas/Environmental-Restoration/Contaminated-Groundwater/Persistent-Contamination/ER-1740 SERDP Management of Contaminants Stored in Low Permeability Zones, A State-of-the-Science Review] <ref name="Sale2013"/>
 
−
|-
 
−
|
 
−
*[https://www.serdp-estcp.org/Tools-and-Training/Environmental-Restoration/Groundwater-Plume-Treatment/Matrix-Diffusion-Tool-Kit ESTCP Matrix Diffusion Toolkit]<ref name="Farhat2012">Farhat, S.K., Newell, C.J., Seyedabbasi, M.A., McDade, J.M., Mahler, N.T., Sale, T.C., Dandy, D.S. and Wahlberg, J.J., 2012. Matrix Diffusion Toolkit. Environmental Security Technology Certification Program (ESTCP) Project ER-201126.  [[Media:Farhat2012ER-201126UsersManual.pdf | User’s Manual.pdf]] Website: [https://www.serdp-estcp.org/Program-Areas/Environmental-Restoration/Contaminated-Groundwater/Persistent-Contamination/ER-201126 ER-201126]</ref>
 
−
|-
 
−
|
 
−
*[https://www.serdp-estcp.org/Program-Areas/Environmental-Restoration/Contaminated-Groundwater/Persistent-Contamination/ER-200530 ESTCP Decision Guide]<ref>Sale, T. and Newell, C., 2011. A Guide for Selecting Remedies for Subsurface Releases of Chlorinated Solvents. Environmental Security Technology Certification Program (ESTCP) Project ER-200530. [[Media: Sale2011ER-200530.pdf | Report.pdf]]  Website: [https://www.serdp-estcp.org/Program-Areas/Environmental-Restoration/Contaminated-Groundwater/Persistent-Contamination/ER-200530 ER-200530]</ref>
 
−
|-
 
−
|
 
−
*[https://www.serdp-estcp.org/Program-Areas/Environmental-Restoration/Contaminated-Groundwater/Persistent-Contamination/ER-201426 ESTCP REMChlor-MD: the USEPA’s REMChlor model with a new matrix diffusion term for the plume]<ref name="Farhat2018">Farhat, S. K., Newell, C. J., Falta, R. W., and Lynch, K., 2018. A Practical Approach for Modeling Matrix Diffusion Effects in REMChlor. Environmental Security Technology Certification Program (ESTCP) Project ER-201426.  [https://enviro.wiki/images/0/0b/2018-Falta-REMChlor_Modeling_Matrix_Diffusion_Effects.pdf  User’s Manual.pdf]  Website: [https://www.serdp-estcp.org/Program-Areas/Environmental-Restoration/Contaminated-Groundwater/Persistent-Contamination/ER-201426 ER-201426]</ref>
 
−
|}
 
−
[[File:ADRFig3.png | thumb| left |400px| Figure 3. Comparison of tracer breakthrough (upper graph) and cleanup curves (lower graph) from advection-dispersion based (gray lines) and advection-diffusion based (black lines) solute transport<ref name="ITRC2011">Interstate Technology and Regulatory Council (ITRC), 2011. Integrated DNAPL Site Strategy (IDSS-1),  Integrated DNAPL Site Strategy Team, ITRC, Washington, DC. [https://www.enviro.wiki/images/d/d9/ITRC-2011-Integrated_DNAPL.pdf Report.pdf]  Free download from: [https://itrcweb.org/GuidanceDocuments/IntegratedDNAPLStrategy_IDSSDoc/IDSS-1.pdf ITRC]</ref>.]]
 
  
−
==Transport Modeling==
+
==Summary==
−
Several different modeling approaches have been developed to simulate the diffusive transport of dissolved solutes into and out of lower ''K'' zones<ref>Falta, R.W., and Wang, W., 2017. A semi-analytical method for simulating matrix diffusion in numerical transport models. Journal of Contaminant Hydrology, 197, pp. 39-49.  [https://doi.org/10.1016/j.jconhyd.2016.12.007 DOI: 10.1016/j.jconhyd.2016.12.007]</ref><ref>Muskus, N. and Falta, R.W., 2018. Semi-analytical method for matrix diffusion in heterogeneous and fractured systems with parent-daughter reactions. Journal of Contaminant Hydrology, 218, pp. 94-109.  [https://doi.org/10.1016/j.jconhyd.2018.10.002 DOI: 10.1016/j.jconhyd.2018.10.002]</ref>.  The [https://www.serdp-estcp.org/Tools-and-Training/Environmental-Restoration/Groundwater-Plume-Treatment/Matrix-Diffusion-Tool-Kit Matrix Diffusion Toolkit]<ref name="Farhat2012"/> is a Microsoft Excel based tool for simulating forward and back diffusion using two different analytical models<ref name="Parker1994">Parker, B.L., Gillham, R.W., and Cherry, J.A., 1994. Diffusive Disappearance of Immiscible Phase Organic Liquids in Fractured Geologic Media. Groundwater, 32(5), pp. 805-820. [https://doi.org/10.1111/j.1745-6584.1994.tb00922.x DOI: 10.1111/j.1745-6584.1994.tb00922.x]</ref><ref>Sale, T.C., Zimbron, J.A., and Dandy, D.S., 2008. Effects of reduced contaminant loading on downgradient water quality in an idealized two-layer granular porous media. Journal of Contaminant Hydrology, 102(1), pp. 72-85. [https://doi.org/10.1016/j.jconhyd.2008.08.002 DOI: 10.1016/j.jconhyd.2008.08.002]</ref>.  Numerical models including [https://en.wikipedia.org/wiki/MODFLOW MODFLOW]/[https://xmswiki.com/wiki/GMS:MT3DMS MT3DMS]<ref name="Zheng1999">Zheng, C. and Wang, P.P., 1999. MT3DMS: A Modular Three-Dimensional Multispecies Transport Model for Simulation of Advection, Dispersion, and Chemical Reactions of Contaminants in Groundwater Systems; Documentation and User’s Guide. Contract Report SERDP-99-1 U.S. Army Engineer Research and Development Center, Vicksburg, MS. [https://www.enviro.wiki/images/3/32/Mt3dmanual.pdf User’s Guide.pdf]  [https://xmswiki.com/wiki/GMS:MT3DMS MT3DMS website]</ref> have been shown to be effective in simulating back diffusion processes and can accurately predict concentration changes over 3 orders-of-magnitude in heterogeneous sand tank experiments<ref>Chapman, S.W., Parker, B.L., Sale, T.C., Doner, L.A., 2012. Testing high resolution numerical models for analysis of contaminant storage and release from low permeability zones. Journal of Contaminant Hydrology, 136, pp. 106-116. [https://doi.org/10.1016/j.jconhyd.2012.04.006 DOI: 10.1016/j.jconhyd.2012.04.006]</ref>. However, numerical models require a fine vertical discretization with short time steps to accurately simulate back diffusion, greatly increasing computation times<ref>Farhat, S.K., Adamson, D.T., Gavaskar, A.R., Lee, S.A., Falta, R.W. and Newell, C.J., 2020. Vertical Discretization Impact in Numerical Modeling of Matrix Diffusion in Contaminated Groundwater. Groundwater Monitoring and Remediation, 40(2), pp. 52-64. [https://doi.org/10.1111/gwmr.12373 DOI: 10.1111/gwmr.12373]</ref>.  These issues can be addressed by incorporating a local 1-D model domain within a general 3D numerical model<ref>Carey, G.R., Chapman, S.W., Parker, B.L. and McGregor, R., 2015. Application of an Adapted Version of MT3DMS for Modeling Back‐Diffusion Remediation Timeframes. Remediation, 25(4), pp. 55-79. [https://doi.org/10.1002/rem.21440 DOI: 10.1002/rem.21440]</ref>.
+
TISR<sup>®</sup> is a cost-effective and adaptable technology that can be customized to address specific site challenges. It can be used as a standalone solution or be integrated with existing remediation strategies to enhance their effectiveness. TISR<sup>®</sup> is particularly effective in challenging hydrogeological conditions and can be optimized to suit specific treatment mechanisms. By shortening the active remediation timeframe, TISR<sup>®</sup> reduces lifecycle costs and minimizes the carbon footprint associated with the remediation process.
−
 
+
<br clear="right"/>
−
The [[REMChlor - MD]] toolkit is capable of simulating matrix diffusion in groundwater contaminant plumes by using a semi-analytical method for estimating mass transfer between high and low permeability zones that provides computationally accurate predictions, with much shorter run times than traditional fine grid numerical models<ref name="Farhat2018"/>.
 
−
 
 
−
==Impacts on Breakthrough Curves==
 
−
 
 
−
The impacts of matrix diffusion on the initial breakthrough of the solute plume and on later cleanup are illustrated in Figure 3<ref name="ITRC2011"/>. Using a traditional advection-dispersion model, the breakthrough curve for a pulse tracer injection appears as a bell-shaped ([[wikipedia:Gaussian function |Gaussian]]) curve (gray line on the right side of the upper graph) where the peak arrival time corresponds to the average groundwater velocity.  Using an advection-diffusion approach, the breakthrough curve for a pulse injection is asymmetric (solid black line) with the peak tracer concentration arriving earlier than would be expected based on the average groundwater velocity, but with a long extended tail to the flushout curve.
 
−
 
 
−
The lower graph shows the predicted cleanup concentration profiles following complete elimination of a source area.  The advection-dispersion model (gray line) predicts a clean-water front arriving at a time corresponding to the average groundwater velocity.  The advection-diffusion model (black line) predicts that concentrations will start to decline more rapidly than expected (based on the average groundwater velocity) as clean water rapidly migrates through the highest-permeability strata. However, low but significant contaminant concentrations linger much longer (tailing) due to diffusive contaminant mass exchange between zones of high and low permeability. A similar response to source remediation is seen in models such as the sand tank experiment shown in Figure 2, and also in field observations of plume contaminant concentrations in heterogeneous aquifers.
 
−
 
 
−
<br clear="left" />
 
  
 
==References==
 
==References==
−
 
 
<references />
 
<references />
  
 
==See Also==
 
==See Also==
−
 
+
[https://vimeo.com/1019489395 TISR<sup>®</sup> Explanation Video]
−
*[http://www.gsi-net.com/en/publications/useful-groundwater-resources/colorado-state-matrix-diffusion-video.html Matrix Diffusion Movie]
 
−
*[https://www.serdp-estcp.org/Program-Areas/Environmental-Restoration/Contaminated-Groundwater/Persistent-Contamination/ER-1737 Impact of Clay-DNAPL Interactions on Transport and Storage of Chlorinated Solvents in Low Permeability Zones]
 
−
*[https://www.serdp-estcp.org/Program-Areas/Environmental-Restoration/Contaminated-Groundwater/Persistent-Contamination/ER-200320 Prediction of Groundwater Quality Improvement Down-Gradient of ''In Situ'' Permeable Treatment Barriers and Fully Remediated Source Zones]
 
−
*[https://www.serdp-estcp.org/Program-Areas/Environmental-Restoration/Contaminated-Groundwater/Persistent-Contamination/ER-201032 Determining Source Attenuation History to Support Closure by Natural Attenuation]
 
−
*[https://www.coursera.org/learn/natural-attenuation-of-groundwater-contaminants/lecture/2R7yh/matrix-diffusion-principles Coursera Matrix Diffusion Online Lecture]
 

Latest revision as of 19:44, 13 October 2026

Thermal In Situ Sustainable Remediation to Enhance Biotic and Abiotic Reactions and Accelerate Remediation Timeframes

Thermal In Situ Sustainable Remediation (TISR®; US Pat. Nos. 10,384,246 and 10,688,545) is a cost-effective and adaptable low temperature thermal remediation technology that accelerates contaminant treatment. It achieves this by enhancing biotic and abiotic contaminant degradation rates through a modest increase in subsurface temperature. TISR® is suitable for a wide range of hydrogeologic settings. It also offers reduced operational costs, a lower carbon footprint, and possibly shorter remedial timeframes than more conventional methods.

Related Article(s):

Contributors: Jonah Munholland, Julia Vidonish, and Craig Divine

Key Resources:

  • Thermal In Situ Sustainable Remediation to Enhance Biotic and Abiotic Reactions and Accelerate Remediation Timeframes, Final Report. ESTCP Project ER20-5028[1].
  • Advances in Low-Temperature Thermal Remediation. Munholland et al., 2024[2].
  • A Design Tool for Solar Thermal Remediation Using Borehole Heat Exchangers. Ornelles, Falta, and Divine, 2023[3].
  • Low-Temperature Thermal Remediation: Gaining Traction as a Green Remedial Alternative. Horst, et al., 2018[4].

Introduction

File:MunhollandFig1.png
Figure 1: Components and layout of a TISR® system

TISR® utilizes borehole heat exchangers (BHEs) to heat target treatment areas in the subsurface. This is achieved through a combination of solar collectors, which harness solar radiation as heat, and the utilization of other heat sources such as waste heat or hybrid heating with heat pumps. That heat is then transferred to the subsurface via a closed loop circulation system connected to the BHEs (Figure 1). By incorporating these additional heat sources, TISR® ensures a more robust and constant heat supply, enabling customization of the system to address specific site challenges and facilitate efficient heat transfer.

The heating of the subsurface through TISR® accelerates various processes such as biodegradation, abiotic reactions, and contaminant desorption and dissolution. The technology is also suitable for diverse hydrogeologic environments, including sites with low permeability zones, due to the relatively uniform thermal conductivity of geologic materials, which is unaffected by grain size[2]. This versatility allows TISR® to integrate with conventional remediation technologies, enhancing their performance.

One of the key advantages of TISR® is its ability to accelerate treatment processes while minimizing energy consumption. By harnessing renewable and sustainable energy sources such as solar radiation and effectively utilizing waste heat or hybrid heating with heat pumps, TISR® delivers an efficient, cost-effective remediation solution. Compatibility with multiple conventional remediation technologies makes it an effective option for addressing a variety of contamination challenges.

Scientific Principles

File:MunhollandFig2.png
Figure 2: Effect of temperature on hydrolysis rates for VOCs

During the TISR® heating process, thermal conduction and advection play a crucial role in boosting physical, biological, and chemical processes within the treatment zones, leading to enhanced attenuation, degradation, and removal of contaminants from the subsurface[5][4]. TISR® systems are typically designed to enhance the biological activity and performance of other active technologies, such as air sparge/ soil vapor extraction (AS/SVE) or chemical oxidation, by increasing the subsurface temperature by approximately 10°C to 20°C. The target groundwater temperature is often set to reach up to about 35°C, which is the optimal temperature for promoting the activity of mesophilic microbial communities responsible for biodegradation of certain contaminants. In cases where the objective is to maximize abiotic hydrolysis mechanisms, such as for some chlorinated alkanes, TISR® systems can be designed to reach a final groundwater temperature of up to 60°C.

The effectiveness of TISR® in enhancing treatment performance has been demonstrated through several mechanisms, which are discussed below:

  • Primary dechlorinating bacteria, such as Dehalococcoides and Dehalogenimonas, are known to be mesophilic. Therefore, increasing the temperature can significantly enhance microbial activity and biodegradation by multiple orders of magnitude[6].
  • Reduced iron minerals, particularly iron sulfides, can participate in the abiotic degradation of chlorinated ethenes and other contaminants. The rates of these reactions generally depend on temperature, following the Arrhenius equation.
  • Rates of other processes that often limit the pace of remediation, such as dissolution, desorption, and back diffusion, are positively correlated with temperature. This results in an enhanced bioavailability of contaminant mass that may otherwise be inaccessible.

These various mechanisms collectively contribute to the improved performance of other active treatments when temperature is moderately increased by utilization of TISR®.

Implementation and Practical Considerations

File:MunhollandFig3.png
Figure 3: Transformation of 1,1-DCE and VC following installation of a TISR® system

TISR® has proven successful in reducing contaminant concentrations across diverse hydrogeologic settings, including those with low and complex hydraulic conductivity conditions. Figure 3 shows a sharp initial decrease in 1,1-dichloroethene (1,1-DCE) concentrations due to enhanced biodegradation, and then a temporary small increase followed by subsequent decreases in 1,1-DCE concentrations to below detection limits, possibly the result of temperature-enhanced desorption or dissolution of 1,1-DCE from the aquifer. There is also a temporary increase and then decrease in the concentrations of vinyl chloride (VC) (a biodegradation product) to very low levels.

The TISR® system construction utilizes off-the-shelf modular components, promoting cost-efficiency, reusability, and a reduced carbon footprint. Waste heat can supplement or replace the solar setup, and remote monitoring through dashboard apps reduces operation and maintenance costs. TISR® projects typically achieve an average capital cost payback within 1 to 3 years due to accelerated rates of remediation.

When implementing TISR®, solar insolation and groundwater velocity must be considered for optimal equipment sizing and cycling. Depending on remedial goals and site history and conditions, the TISR® system and target temperatures may be designed to enhance specific remedial mechanisms (e.g. hydrolysis over bioremediation). Recently Ornelles et al.[3] developed an easy to use Excel-based model that can be used to optimize TISR® design and predict subsurface temperature changes over time. Frequent monitoring of the temperature and microbial community composition relative to targets is useful for evaluating treatment effectiveness and optimizing system performance. The system and target temperatures can be customized to enhance specific remedial mechanisms based on site conditions and goals.

Summary

TISR® is a cost-effective and adaptable technology that can be customized to address specific site challenges. It can be used as a standalone solution or be integrated with existing remediation strategies to enhance their effectiveness. TISR® is particularly effective in challenging hydrogeological conditions and can be optimized to suit specific treatment mechanisms. By shortening the active remediation timeframe, TISR® reduces lifecycle costs and minimizes the carbon footprint associated with the remediation process.

References

  1. ^ Divine, C., Munholland, J., Zardouzian, E., Justicia-Leon, S., Aspinall, J.V., Randhawa, D., Falta, R., Freedman, D., Becker, M., 2025. Thermal In Situ Sustainable Remediation to Enhance Biotic and Abiotic Reactions and Accelerate Remediation Timeframes, Final Report. Environmental Security Technology Certification Program (ESTCP), Project ER20-5028. Project Website  Final Report.pdf
  2. ^ 2.0 2.1 Munholland, J, Rosso, D., Randhawa, D., Devine, C., Pennington, A., 2024. Advances in Low-Temperature Thermal Remediation. In: García-Rincón, J., Gatsios, E., Lenhard, R.J., Atekwana, E.A., Naidu, R. (eds), Advances in the Characterisation and Remediation of Sites Contaminated with Petroleum Hydrocarbons, Chapter 18 pp. 623-653. Environmental Contamination Remediation and Management series, Springer Nature. doi: 10.1007/978-3-031-34447-3_18  Open Access Chapter
  3. ^ 3.0 3.1 Ornelles, A.D., Falta, R.W., Divine, C.E., 2023. A Design Tool for Solar Thermal Remediation Using Borehole Heat Exchangers. Ground Water, 61(2), pp. 245-254. doi: 10.1111/gwat.13265  Free download from NGWA
  4. ^ 4.0 4.1 Horst, J., Flanders, C., Klemmer, M., Randhawa, D.S., Rosso, D., 2018. Low-Temperature Thermal Remediation: Gaining Traction as a Green Remedial Alternative. Groundwater Monitoring and Remediation, 38(3), pp. 18-27. doi: 10.1111/gwmr.12295
  5. ^ Dettmer, K., 2002. A Discussion of the Effects of Thermal Remediation Treatments on Microbial Degradation Processes. U.S. Environmental Protection Agency, Office of Solid Waste and Emergency Response, Technology Innovation Office, Washington, DC. free report  free download from clu-in.org
  6. ^ Macbeth, T., Truex, M., Powell, T., Michalsen, M., 2012. Combining Low-Energy Electrical Resistance Heating with Biotic and Abiotic Reactions for Treatment of Chlorinated Solvent DNAPL Source Areas. Environmental Security Technology Certification Program (ESTCP) Project ER-200719 webpage  free download  Project Summary Presentation
  7. ^ Suthersan, S., Horst, J., Klemmer, M., Malone, D., 2012. Temperature-Activated Auto-Decomposition Reactions: An Under-Utilized In Situ Remediation Solution. Groundwater Monitoring and Remediation, 32(3), pp. 34-40. doi: 10.1111/j.1745-6592.2012.01407.x
  8. ^ Chen, F., Freedman, D.L., Falta, R.W., Murdoch, L.C., 2012. Henry's law constants of chlorinated solvents at elevated temperatures. Chemosphere, 86(2), pp.156-165. doi: 10.1016/j.chemosphere.2011.10.004

See Also

TISR® Explanation Video