Difference between revisions of "User:Jhurley/sandbox"

From Enviro Wiki
Jump to: navigation, search
 
Line 1: Line 1:
−
The persistent release of residual contaminants from low hydraulic conductivity (low ''k'') zones prevents many chlorinated solvent sites from reaching groundwater cleanup goals. Low ''k'' aquifer settings limit the effectiveness of many conventional remediation technologies that rely on extraction, recirculation, or amendment delivery and distribution to achieve contact between the residual contaminants and the reagents, contact which is necessary for subsequent contaminant transformation or destruction. Alternative methods are needed to effectively distribute remedial amendments, to control contaminants leaving low ''k'' source zones, and to enhance natural attenuation processes. Two innovative remediation technologies for the treatment of chlorinated solvents and other contaminants in low ''k'' media are introduced, along with operational and performance results from recent field demonstrations.
+
==Thermal In Situ Sustainable Remediation to Enhance Biotic and Abiotic Reactions and Accelerate Remediation Timeframes==
 +
Thermal In Situ Sustainable Remediation (TISR<sup>®</sup>; US Pat. Nos. 10,384,246 and 10,688,545) is a cost-effective and adaptable low temperature thermal remediation technology that accelerates contaminant treatment. It achieves this by enhancing biotic and abiotic contaminant degradation rates through a modest increase in subsurface temperature. TISR<sup>®</sup> is suitable for a wide range of hydrogeologic settings. It also offers reduced operational costs, a lower carbon footprint, and possibly shorter remedial timeframes than more conventional methods.
 
<div style="float:right;margin:0 0 2em 2em;">__TOC__</div>
 
<div style="float:right;margin:0 0 2em 2em;">__TOC__</div>
  
 
'''Related Article(s):'''
 
'''Related Article(s):'''
−
* [[Bioremediation - Anaerobic | Anaerobic Bioremediation]]
 
−
* [[Chemical Oxidation (In Situ - ISCO) | In Situ Chemical Oxidation]]
 
−
* [[Chemical Reduction (In Situ - ISCR) | In Situ Chemical Reduction]]
 
  
−
'''CONTRIBUTOR(S): '''
+
*[[Thermal Remediation]]
−
* [[Stephen D. Richardson, Ph.D., PE]]
+
*[[Thermal Remediation - Electrical Resistance Heating | Electrical Resistance Heating]]
−
* [[Craig E. Divine, Ph.D., PG]]
+
*[[Thermal Conduction Heating (TCH)]]
 +
*[[Thermal Remediation - Combined Remedies | Combined Remedies]]
  
−
'''Key Resource(s):'''
+
'''Contributors:''' Jonah Munholland, Julia Vidonish, and Craig Divine
−
* The Horizontal Reactive Media Treatment Well (HRX Well<sup>&reg;</sup>) for Passive In-Situ Remediation<ref name="Divine2018a">Divine, C. E., Roth, T, Crimi, M., DiMarco, A.C., Spurlin, M., Gillow, J., and Leone, G., 2018. The Horizontal Reactive Media Treatment Well (HRX Well<sup>&reg;</sup>) for Passive In-Situ Remediation. Groundwater Monitoring & Remediation, 38(1), pp. 56–65.  [https://doi.org/10.1111/gwmr.12252 DOI: 10.1111/gwmr.12252]</ref>
 
  
−
* The Horizontal Reactive Media Treatment Well (HRX Well<sup>&reg;</sup>) for Passive In Situ Remediation: Design, Implementation, and Sustainability Considerations<ref name="Divine2018">Divine, C.E., Wright, J., Wang, J., McDonough, J., Kladias, M., Crimi, M., Nzeribe, B.N., Devlin, J.F., Lubrecht, M., Ombalski, D., Hodge, B., Voscott, H., and Gerber, K., 2018. The Horizontal Reactive Media Treatment Well (HRX Well<sup>&reg;</sup>) for Passive In Situ Remediation: Design, Implementation, and Sustainability Considerations. Remediation, 28(4), pp. 5-16. [https://doi.org/10.1002/rem.21571 DOI: 10.1002/rem.21571]&nbsp;&nbsp; Also available from: [https://www.researchgate.net/publication/327487096_The_horizontal_reactive_media_treatment_well_HRX_WellR_for_passive_in_situ_remediation_Design_implementation_and_sustainability_considerations ResearchGate]</ref>
+
'''Key Resources:'''
 +
*Thermal In Situ Sustainable Remediation to Enhance Biotic and Abiotic Reactions and Accelerate Remediation Timeframes, Final Report. ESTCP Project ER20-5028<ref>Divine, C., Munholland, J., Zardouzian, E., Justicia-Leon, S., Aspinall, J.V., Randhawa, D., Falta, R., Freedman, D., Becker, M., 2025. Thermal In Situ Sustainable Remediation to Enhance Biotic and Abiotic Reactions and Accelerate Remediation Timeframes, Final Report. Environmental Security Technology Certification Program (ESTCP), Project ER20-5028. [https://serdp-estcp.mil/projects/details/bab4bc87-b4bc-42df-ad0e-11ea0adf27dc/er20-5028-project-overview Project Website]&nbsp; [[Media: ER20-5028 FR DevineEtAl2025.pdf | Final Report.pdf]]</ref>.
  
−
* New Application of A Geotechnical Technology to Remediate Low-Permeability Contaminated Media – Final Technical Report<ref name="Richardson2020">Richardson, S.D., Hart, D.M., Long, J.A., and Newell, C.J., 2020. New Application of A Geotechnical Technology to Remediate Low-Permeability Contaminated Media – Final Technical Report. ER-201627, Environmental Security Technology Certification Program (ESTCP). [https://www.serdp-estcp.org/Program-Areas/Environmental-Restoration/Contaminated-Groundwater/Persistent-Contamination/ER-201627/ Project Overview]</ref>
+
*Advances in Low-Temperature Thermal Remediation. Munholland ''et al.'', 2024<ref name="MunhollandEtAl2024">Munholland, J, Rosso, D., Randhawa, D., Devine, C., Pennington, A., 2024. Advances in Low-Temperature Thermal Remediation. In: García-Rincón, J., Gatsios, E., Lenhard, R.J., Atekwana, E.A., Naidu, R. (eds), Advances in the Characterisation and Remediation of Sites Contaminated with Petroleum Hydrocarbons, Chapter 18 pp. 623-653. Environmental Contamination Remediation and Management series, Springer Nature. [https://doi.org/10.1007/978-3-031-34447-3_18 doi: 10.1007/978-3-031-34447-3_18]&nbsp; [[Media: MunhollandEtAl2024.pdf | Open Access Chapter]]</ref>.
 +
 
 +
*A Design Tool for Solar Thermal Remediation Using Borehole Heat Exchangers. Ornelles, Falta, and Divine, 2023<ref name="Ornelles">Ornelles, A.D., Falta, R.W., Divine, C.E., 2023. A Design Tool for Solar Thermal Remediation Using Borehole Heat Exchangers. Ground Water, 61(2), pp. 245-254. [https://doi.org/10.1111/gwat.13265 doi: 10.1111/gwat.13265]&nbsp; [https://ngwa.onlinelibrary.wiley.com/doi/epdf/10.1111/gwat.13265 Free download from NGWA]</ref>.
 +
 
 +
*Low-Temperature Thermal Remediation: Gaining Traction as a Green Remedial Alternative. Horst, ''et al.'', 2018<ref name="HorstEtAl2018">Horst, J., Flanders, C., Klemmer, M., Randhawa, D.S., Rosso, D., 2018. Low-Temperature Thermal Remediation: Gaining Traction as a Green Remedial Alternative. Groundwater Monitoring and Remediation, 38(3), pp. 18-27. [https://doi.org/10.1111/gwmr.12295 doi: 10.1111/gwmr.12295]</ref>.
  
 
==Introduction==
 
==Introduction==
−
[[File:Richardson1w2Fig1.png | thumb | 400px | Figure 1. Examples of low ''k'' geology. Upper left: bay muds, Oakland, California; lower left: weathered siltstone, Denver, Colorado; right: tailings slimes, central New Mexico<ref name="Horst2019"/>.]]
+
[[File: MunhollandFig1.png | thumb | 500 px | Figure 1: Components and layout of a TISR<sup>®</sup> system]]
−
[[File:Richardson1w2Fig2.png | thumb | 400px | Figure 2. Contaminant back diffusion (“Matrix Diffusion”) from low ''k'' zones<ref name="NRC2005">National Research Council, 2005. Contaminants in the Subsurface: Source Zone Assessment and Remediation. National Academies Press, Washington, DC, pp. 372. [https://doi.org/10.17226/11146 DOI: 10.17226/11146]&nbsp;&nbsp; [[Media: NRC2005.pdf | Book.pdf]]</ref>.]]
+
TISR<sup>®</sup> utilizes [[Wikipedia: Downhole heat exchanger | borehole heat exchangers (BHEs)]] to heat target treatment areas in the subsurface. This is achieved through a combination of solar collectors, which harness solar radiation as heat, and the utilization of other heat sources such as waste heat or hybrid heating with heat pumps. That heat is then transferred to the subsurface via a closed loop circulation system connected to the BHEs (Figure 1). By incorporating these additional heat sources, TISR<sup>®</sup> ensures a more robust and constant heat supply, enabling customization of the system to address specific site challenges and facilitate efficient heat transfer.
−
A critical challenge preventing many chlorinated solvent sites from achieving groundwater cleanup goals is the long term release of residual contaminants from low hydraulic conductivity (low ''k'') zones such as silts, clays, glacial till, over-bank deposits, marine deposits, tailings “slimes”, saprolite and bedrock (see Figure 1)<ref name ="Horst2019">Horst, J., Divine, C., Schnobrich, M., Oesterreich, R., and Munholland, J., 2019. Groundwater Remediation in Low-Permeability Settings: The Evolving Spectrum of Proven and Potential. Groundwater Monitoring & Remediation, 39(1), pp. 11-19. [https://doi.org/10.1111/gwmr.12316 DOI: 10.1111/gwmr.12316]</ref><ref name ="Sale2008">Sale, T., C. Newell, H. Stroo, R. Hinchee, and Johnson, P., 2008. Frequently Asked Questions Regarding Management of Chlorinated Solvents in Soils and Groundwater. Environmental Security Technology Certification Program (ESTCP) Project ER-0530, 38 pp. [[Media:2008-Sale-Frequently_Asked_Questions_Regarding_Management_of_Chlorinated_Solvent_in_Soils_and_Groundwater.pdf  | Report.pdf]]&nbsp;&nbsp; [https://serdp-estcp.org/Program-Areas/Environmental-Restoration/Contaminated-Groundwater/Persistent-Contamination/ER-200530/(language)/eng-US Project overview]</ref>. Such sites may be dominated by matrix diffusion processes (see Figure 2) which can significantly prolong restoration and site management timeframes. Residual contaminants residing in low permeability zones slowly diffuse from the low ''k'' matrix back into higher permeability zones, becoming a persistent source that is very difficult to remediate. One of the side effects of matrix diffusion is concentration rebound after an ''in situ'' treatment is applied. This is commonly observed at sites treated with chemical oxidation<ref name="McGuire2006">McGuire, T.M., McDade, J.M., and Newell, C.J., 2006. Performance of DNAPL Source Depletion Technologies at 59 Chlorinated Solvent-Impacted Sites. Groundwater Monitoring & Remediation. Volume 26, Issue 1, pp. 73-84.  [https://doi.org/10.1111/j.1745-6592.2006.00054.x DOI: 10.1111/j.1745-6592.2006.00054.x]&nbsp;&nbsp; [https://www.provectusenvironmental.com/marketing/p-ox1/McGuire%20et%20al%202006.pdf  Free download.pdf]</ref><ref name="Krembs2010">Krembs, F., Siegrist, R., Crimi, M., Furrer, R., and Petri, B., 2010. ISCO for Groundwater Remediation: Analysis of Field Applications and Performance. Groundwater Monitoring & Remediation, 30(4), pp. 42-53.  [https://doi.org/10.1111/j.1745-6592.2010.01312.x DOI: 10.1111/j.1745-6592.2010.01312.x]</ref> and has the potential to occur at ''in situ'' bioremediation sites after the depletion of electron donors<ref name="Adamson2011">Adamson, D., McGuire, T., Newell, C., and Stroo, H., 2011. Sustained Treatment: Implications for Treatment Timescales Associated with Source-Depletion Technologies. Remediation, 21(2), pp. 27-50.  [https://doi.org/10.1002/rem.20280 DOI: 10.1002/rem.20280]</ref>.
 
  
−
Currently, there are limited remediation options available to treat residual contamination trapped in low ''k'' zones. Low ''k'' settings limit the applicability and effectiveness of conventional remediation technologies due to the constraint on fluid introduction and recovery. As such, methods relying on extraction, recirculation, or reagent delivery and distribution are often limited in their effectiveness. For the long lived, difficult to treat sites, innovative technologies are needed that will reliably address mass flux limitations of contaminants leaving low ''k'' source zones, and also increase the actual treatment of the contaminants leaving these low ''k'' zones by enhancing natural attenuation processes. Two innovative technologies investigated by ESTCP are summarized below.
+
The heating of the subsurface through TISR<sup>®</sup> accelerates various processes such as biodegradation, abiotic reactions, and contaminant desorption and dissolution. The technology is also suitable for diverse hydrogeologic environments, including sites with low permeability zones, due to the relatively uniform thermal conductivity of geologic materials, which is unaffected by grain size<ref name="MunhollandEtAl2024"/>. This versatility allows TISR<sup>®</sup> to integrate with conventional remediation technologies, enhancing their performance.
  
−
==“Grout Bomber”==
+
One of the key advantages of TISR<sup>®</sup> is its ability to accelerate treatment processes while minimizing energy consumption. By harnessing renewable and sustainable energy sources such as solar radiation and effectively utilizing waste heat or hybrid heating with heat pumps, TISR<sup>®</sup> delivers an efficient, cost-effective remediation solution. Compatibility with multiple conventional remediation technologies makes it an effective option for addressing a variety of contamination challenges.
−
===Technology Description===
 
−
[[File:Richardson1w2Fig3.png | thumb | 400px | Figure 3. a) Grout Bomber equipment; b) hopper for mixing and delivery of grout to the “stitcher”; and c) grout exiting the mandrel]]
 
−
[[File:Richardson1w2Fig4.png | thumb | 400px | Figure 4. Application of the Bomber technology for contaminated sites in low ''k'' materials.]]
 
−
[[File:Richardson1w2Fig5.png | thumb | 400px | Figure 5. Chlorinated ethene concentrations at well pair (CMT-1 and IS17MW04).]]
 
−
The geotechnical industry offers a variety of well-established techniques for quickly and efficiently accessing the subsurface for the purposes of ground stabilization, foundation rehabilitation, porewater drainage, and structural support. The speed and efficiency of these techniques can also be a major advantage for emplacement of remedial amendments into the subsurface. One promising approach is the Grout Bomber, a larger adaptation of conventional cement or compaction grouting techniques for subsurface stabilization. The technology uses an excavator equipped with specialized equipment (a “stitcher”) to quickly push a mandrel (3.5 in. diameter hollow cylindrical rod) into the subsurface and subsequently fill the hole and subsurface voids with cement grout (from bottom to top) using an in-line grout delivery system. The typical arrangement of the Grout Bomber technology includes the installation rig (excavator with the “stitcher” mast; see Figure 3a) and an on-site grout mixing and delivery unit consisting of mixing hopper, pumps, hosing, and power supply. Raw materials are loaded into the mixing hopper (see Figure 3b) where it is mixed to the appropriate consistency, then pumped to the Bomber rig at a rate of approximately 0.25 cubic feet per pump stroke. At the exit end of the Bomber mandrel (see Figure 3c), the grout flows in a continuous and uniform manner, allowing the columns to be emplaced with grout while the mandrel (which was pushed into the subsurface) is lifted to the surface.  Hundreds of closely spaced vertical grout columns can be installed per day using this technology.
 
  
−
For environmental applications, the Grout Bomber approach can be “repurposed” as a means to improve delivery of remediation amendments into contaminated treatment zones in low ''k'' materials. The remedial amendment (e.g., mixture of zero-valent iron (ZVI), sand, neat oil) can replace the grout and be directly placed into the subsurface from bottom to top (not injected into the surrounding formation), creating hundreds of reaction columns. The Bomber technology offers the following benefits:  
+
==Scientific Principles==
−
* '''Reduces uncertainty: '''
+
[[File: MunhollandFig2.png | thumb | 500 px | Figure 2: Effect of temperature on hydrolysis rates for VOCs]]
−
The Bomber technology circumvents the “delivery problem” associated with conventional injection-based remediation approaches, particularly in low ''k'' zones. The closely spaced nature of the reaction columns (2-3 ft spacing) reduces the diffusion lengths out of low ''k'' zones and also the uncertainty associated with amendment delivery because contaminants are always < 1 - 1.5 ft from an active treatment zone (see Figure 4).  
+
During the TISR<sup>®</sup> heating process, thermal conduction and advection play a crucial role in boosting physical, biological, and chemical processes within the treatment zones, leading to enhanced attenuation, degradation, and removal of contaminants from the subsurface<ref>Dettmer, K., 2002. A Discussion of the Effects of Thermal Remediation Treatments on Microbial Degradation Processes. U.S. Environmental Protection Agency, Office of Solid Waste and Emergency Response, Technology Innovation Office, Washington, DC. [[Media: dettmer2002.pdf | free report]]&nbsp; [https://www.clu-in.org/download/techdrct/dettmer.pdf free download from clu-in.org]</ref><ref name="HorstEtAl2018"/>. TISR<sup>®</sup> systems are typically designed to enhance the biological activity and performance of other active technologies, such as [[Wikipedia: Air sparging | air sparge]]/[[Soil Vapor Extraction (SVE) | soil vapor extraction]] (AS/SVE) or [[Chemical Oxidation (In Situ - ISCO) | chemical oxidation]], by increasing the subsurface temperature by approximately 10°C to 20°C. The target groundwater temperature is often set to reach up to about 35°C, which is the optimal temperature for promoting the activity of mesophilic microbial communities responsible for biodegradation of certain contaminants. In cases where the objective is to maximize abiotic hydrolysis mechanisms, such as for some chlorinated alkanes, TISR<sup>®</sup> systems can be designed to reach a final groundwater temperature of up to 60°C.
  
−
* '''Rapid installation of reaction columns: '''
+
The effectiveness of TISR<sup>®</sup> in enhancing treatment performance has been demonstrated through several mechanisms, which are discussed below:
−
The Grout Bomber can install 100+ reaction columns per day to depths of 40-50 ft below ground surface (bgs) to encourage contaminant degradation in source zones. Since the Grout Bomber is a direct push technique, it is better suited to silts and clays with blow counts < 35. Consolidated materials with higher blow counts will require additional equipment to pre-drill the columns prior to amendment emplacement. In general, this technology represents a much simpler, less intensive, and easier to install version of complete soil mixing.
 
  
−
* '''Accommodates various amendment types: '''
+
*Primary dechlorinating bacteria, such as [[Wikipedia: Dehalococcoides | Dehalococcoides]] and [[Wikipedia: Dehalogenimonas | Dehalogenimonas]], are known to be [[Wikipedia: Mesophile | mesophilic]]. Therefore, increasing the temperature can significantly enhance microbial activity and biodegradation by multiple orders of magnitude<ref>Macbeth, T., Truex, M., Powell, T., Michalsen, M., 2012. Combining Low-Energy Electrical Resistance Heating with Biotic and Abiotic Reactions for Treatment of Chlorinated Solvent DNAPL Source Areas. [https://serdp-estcp.mil/ Environmental Security Technology Certification Program (ESTCP)] [https://serdp-estcp.mil/projects/details/877a3b41-6bed-4f4a-b43a-87fbcd9b7f0b/er-200719-project-overview Project ER-200719 webpage]&nbsp; [[Media: Macbeth2012_ER-200719-FR.pdf | free download]]&nbsp; [https://www.youtube.com/watch?v=-EbwKbs8scE Project Summary Presentation]</ref>.
−
In one example<ref name="Richardson2020"/>, vertical reaction columns containing a mixture of ZVI, vegetable oil, sand and minor amounts of water were installed to a depth of 30 ft bgs in a low ''k'' treatment area consisting primarily of silts, sandy clays, and lean clays<ref name="Divine2018"/>. The ZVI-sand-oil mixture was designed to have a similar consistency (or viscosity) to cement grout, thus requiring no major alterations to the existing Bomber equipment for the project. Recommended practices to ensure uninterrupted flow of amendments to the Bomber mandrel include:  
 
−
** Conduct simple pumping pilot studies with amendments of varying consistencies,
 
−
** Consult with a well trained pump operator, and
 
−
** Minimize the length of hosing between mixing hopper pump and Bomber mandrel.  
 
  
−
* '''Cost effective source zone treatment: '''
+
*Reduced iron minerals, particularly iron sulfides, can participate in the abiotic degradation of chlorinated ethenes and other contaminants. The rates of these reactions generally depend on temperature, following the [[Wikipedia: Arrhenius equation | Arrhenius equation]].
−
Estimated treatment costs associated with emplacement of amendments with the Grout Bomber are ~$35 per cubic yard of source zone treated (including contractor labor, equipment, and materials). This is generally less than the reported unit cost for ''in situ'' biodegradation ($20-$80/yd<sup>3</sup>) and significantly less than chemical oxidation ($125/yd<sup>3</sup>) and thermal remediation (median $200/yd<sup>3</sup>)<ref name="McDade2005">McDade, J.M., T.M. McGuire, and Newell, C.J., 2005. Analysis of DNAPL Source Depletion Costs at 36 Field Sites, Remediation, 15(2), pp. 9-18.  [https://doi.org/10.1002/rem.20039 DOI: 10.1002/rem.20039]</ref>.
 
  
−
===Operational Approach & Results===
+
*[[Wikipedia: Hydrolysis | Hydrolysis]] rates for certain compounds exhibit high temperature dependence. For example, a 10°C increase can lead to a 50% reduction in the half-life of [[Wikipedia: 1,1,1-Trichloroethane | 1,1,1-trichloroethane (1,1,1-TCA)]]<ref>Suthersan, S., Horst, J., Klemmer, M., Malone, D., 2012. Temperature-Activated Auto-Decomposition Reactions: An Under-Utilized In Situ Remediation Solution. Groundwater Monitoring and Remediation, 32(3), pp. 34-40. [https://doi.org/10.1111/j.1745-6592.2012.01407.x doi: 10.1111/j.1745-6592.2012.01407.x]</ref>. Figure 2 presents the calculated temperature-dependent hydrolysis rates for 13 common [[Wikipedia: Volatile organic compound | volatile organic compounds (VOCs)]] at a pH of 7.
−
A field demonstration was conducted at Site 17, Naval Support Facility Indian Head, Maryland. The treatment area consists primarily of silts, sandy clays, and lean clays with TCE concentrations in soil and groundwater of up to 250 mg/kg and 400 mg/L, respectively. Eight hundred reaction columns (consisting of ZVI/sand or oil/sand), were installed 2-3 ft apart, to a depth of 30 ft bgs at the site. Approximately 100 reaction columns were installed per day, with the most productive day totaling 180 columns. During operation, installation time for each reaction column was on the order of 1-2 minutes. Overall, 77,000 lbs of ZVI and 650 gallons of vegetable oil were emplaced within the source area of ~5,000 ft<sup>2</sup>.  
 
  
−
===Performance Results===
+
*[[Wikipedia: Henry's law | Henry's Law]] constant, [[Wikipedia: Vapor pressure | vapor pressure]], solubility, and viscosity values are also temperature dependent. For instance, the Henry's Law constant values for many VOCs, including [[Wikipedia: Tetrachloroethylene | tetrachloroethene (PCE)]], have been observed to double between 8 and 24°C<ref>Chen, F., Freedman, D.L., Falta, R.W., Murdoch, L.C., 2012. Henry's law constants of chlorinated solvents at elevated temperatures. Chemosphere, 86(2), pp.156-165. [https://doi.org/10.1016/j.chemosphere.2011.10.004 doi: 10.1016/j.chemosphere.2011.10.004]</ref>.
−
Ongoing post installation monitoring of treatment area groundwater has found moderate reductions in TCE in site monitoring wells and that key degradation products that serve as indicators for both abiotic and biotic mechanisms (i.e., acetylene, ethene/ethane) are present. Samples from Continuous Multilevel Tubing (CMT) wells installed within reaction columns (anulus filled with ZVI amendment) have demonstrated 1-3 orders of magnitude reductions in TCE relative to the surrounding formation water (see Figure 5). These results provide evidence that the reaction columns are creating steep concentration gradients that could drive contaminants out of low permeability zones. Further, gaseous products (e.g., propane, propene, i-butane, n-butane, n-pentane, n-hexane) were detected in the unsaturated zone of several reaction columns further supporting abiotic TCE degradation. Results of this full scale project were very promising and, although several operational improvements were identified (e.g., improved pumpability of ZVI/sand mixture; minor equipment modifications; improved site prep practices), the Bomber technology has the potential to be an important remediation alternative for hard-to-treat chlorinated source zones, particularly ones with large, persistent matrix diffusion sources over large areas.
+
 
 +
*Rates of other processes that often limit the pace of remediation, such as dissolution, desorption, and [[Matrix Diffusion | back diffusion]], are positively correlated with temperature. This results in an enhanced bioavailability of contaminant mass that may otherwise be inaccessible.
 +
 
 +
These various mechanisms collectively contribute to the improved performance of other active treatments when temperature is moderately increased by utilization of TISR®.
 +
 
 +
==Implementation and Practical Considerations==
 +
[[File: MunhollandFig3.png | thumb | 500 px | Figure 3: Transformation of 1,1-DCE and VC following installation of a TISR<sup>®</sup> system]]
 +
TISR<sup>®</sup> has proven successful in reducing contaminant concentrations across diverse hydrogeologic settings, including those with low and complex hydraulic conductivity conditions. Figure 3 shows a sharp initial decrease in [[Wikipedia: 1,1-Dichloroethylene | 1,1-dichloroethene (1,1-DCE)]] concentrations due to enhanced biodegradation, and then a temporary small increase followed by subsequent decreases in 1,1-DCE concentrations to below detection limits, possibly the result of temperature-enhanced desorption or dissolution of 1,1-DCE from the aquifer. There is also a temporary increase and then decrease in the concentrations of [[Wikipedia: Vinyl chloride | vinyl chloride (VC)]] (a biodegradation product) to very low levels.
 +
 
 +
The TISR<sup>®</sup> system construction utilizes off-the-shelf modular components, promoting cost-efficiency, reusability, and a reduced carbon footprint. Waste heat can supplement or replace the solar setup, and remote monitoring through dashboard apps reduces operation and maintenance costs. TISR® projects typically achieve an average capital cost payback within 1 to 3 years due to accelerated rates of remediation.
 +
 
 +
When implementing TISR<sup>®</sup>, [[Wikipedia: Solar irradiance | solar insolation]] and groundwater velocity must be considered for optimal equipment sizing and cycling. Depending on remedial goals and site history and conditions, the TISR<sup>®</sup> system and target temperatures may be designed to enhance specific remedial mechanisms (e.g. hydrolysis over bioremediation). Recently Ornelles ''et al.''<ref name="Ornelles"/> developed an easy to use Excel-based model that can be used to optimize TISR<sup>®</sup> design and predict subsurface temperature changes over time. Frequent monitoring of the temperature and microbial community composition relative to targets is useful for evaluating treatment effectiveness and optimizing system performance. The system and target temperatures can be customized to enhance specific remedial mechanisms based on site conditions and goals.
 +
 
 +
==Summary==
 +
TISR<sup>®</sup> is a cost-effective and adaptable technology that can be customized to address specific site challenges. It can be used as a standalone solution or be integrated with existing remediation strategies to enhance their effectiveness. TISR<sup>®</sup> is particularly effective in challenging hydrogeological conditions and can be optimized to suit specific treatment mechanisms. By shortening the active remediation timeframe, TISR<sup>®</sup> reduces lifecycle costs and minimizes the carbon footprint associated with the remediation process.
 +
<br clear="right"/>
  
 
==References==
 
==References==
−
 
+
<references />
−
<references/>
 
  
 
==See Also==
 
==See Also==
 +
[https://vimeo.com/1019489395 TISR<sup>®</sup> Explanation Video]

Latest revision as of 19:44, 13 October 2026

Thermal In Situ Sustainable Remediation to Enhance Biotic and Abiotic Reactions and Accelerate Remediation Timeframes

Thermal In Situ Sustainable Remediation (TISR®; US Pat. Nos. 10,384,246 and 10,688,545) is a cost-effective and adaptable low temperature thermal remediation technology that accelerates contaminant treatment. It achieves this by enhancing biotic and abiotic contaminant degradation rates through a modest increase in subsurface temperature. TISR® is suitable for a wide range of hydrogeologic settings. It also offers reduced operational costs, a lower carbon footprint, and possibly shorter remedial timeframes than more conventional methods.

Related Article(s):

Contributors: Jonah Munholland, Julia Vidonish, and Craig Divine

Key Resources:

  • Thermal In Situ Sustainable Remediation to Enhance Biotic and Abiotic Reactions and Accelerate Remediation Timeframes, Final Report. ESTCP Project ER20-5028[1].
  • Advances in Low-Temperature Thermal Remediation. Munholland et al., 2024[2].
  • A Design Tool for Solar Thermal Remediation Using Borehole Heat Exchangers. Ornelles, Falta, and Divine, 2023[3].
  • Low-Temperature Thermal Remediation: Gaining Traction as a Green Remedial Alternative. Horst, et al., 2018[4].

Introduction

File:MunhollandFig1.png
Figure 1: Components and layout of a TISR® system

TISR® utilizes borehole heat exchangers (BHEs) to heat target treatment areas in the subsurface. This is achieved through a combination of solar collectors, which harness solar radiation as heat, and the utilization of other heat sources such as waste heat or hybrid heating with heat pumps. That heat is then transferred to the subsurface via a closed loop circulation system connected to the BHEs (Figure 1). By incorporating these additional heat sources, TISR® ensures a more robust and constant heat supply, enabling customization of the system to address specific site challenges and facilitate efficient heat transfer.

The heating of the subsurface through TISR® accelerates various processes such as biodegradation, abiotic reactions, and contaminant desorption and dissolution. The technology is also suitable for diverse hydrogeologic environments, including sites with low permeability zones, due to the relatively uniform thermal conductivity of geologic materials, which is unaffected by grain size[2]. This versatility allows TISR® to integrate with conventional remediation technologies, enhancing their performance.

One of the key advantages of TISR® is its ability to accelerate treatment processes while minimizing energy consumption. By harnessing renewable and sustainable energy sources such as solar radiation and effectively utilizing waste heat or hybrid heating with heat pumps, TISR® delivers an efficient, cost-effective remediation solution. Compatibility with multiple conventional remediation technologies makes it an effective option for addressing a variety of contamination challenges.

Scientific Principles

File:MunhollandFig2.png
Figure 2: Effect of temperature on hydrolysis rates for VOCs

During the TISR® heating process, thermal conduction and advection play a crucial role in boosting physical, biological, and chemical processes within the treatment zones, leading to enhanced attenuation, degradation, and removal of contaminants from the subsurface[5][4]. TISR® systems are typically designed to enhance the biological activity and performance of other active technologies, such as air sparge/ soil vapor extraction (AS/SVE) or chemical oxidation, by increasing the subsurface temperature by approximately 10°C to 20°C. The target groundwater temperature is often set to reach up to about 35°C, which is the optimal temperature for promoting the activity of mesophilic microbial communities responsible for biodegradation of certain contaminants. In cases where the objective is to maximize abiotic hydrolysis mechanisms, such as for some chlorinated alkanes, TISR® systems can be designed to reach a final groundwater temperature of up to 60°C.

The effectiveness of TISR® in enhancing treatment performance has been demonstrated through several mechanisms, which are discussed below:

  • Primary dechlorinating bacteria, such as Dehalococcoides and Dehalogenimonas, are known to be mesophilic. Therefore, increasing the temperature can significantly enhance microbial activity and biodegradation by multiple orders of magnitude[6].
  • Reduced iron minerals, particularly iron sulfides, can participate in the abiotic degradation of chlorinated ethenes and other contaminants. The rates of these reactions generally depend on temperature, following the Arrhenius equation.
  • Rates of other processes that often limit the pace of remediation, such as dissolution, desorption, and back diffusion, are positively correlated with temperature. This results in an enhanced bioavailability of contaminant mass that may otherwise be inaccessible.

These various mechanisms collectively contribute to the improved performance of other active treatments when temperature is moderately increased by utilization of TISR®.

Implementation and Practical Considerations

File:MunhollandFig3.png
Figure 3: Transformation of 1,1-DCE and VC following installation of a TISR® system

TISR® has proven successful in reducing contaminant concentrations across diverse hydrogeologic settings, including those with low and complex hydraulic conductivity conditions. Figure 3 shows a sharp initial decrease in 1,1-dichloroethene (1,1-DCE) concentrations due to enhanced biodegradation, and then a temporary small increase followed by subsequent decreases in 1,1-DCE concentrations to below detection limits, possibly the result of temperature-enhanced desorption or dissolution of 1,1-DCE from the aquifer. There is also a temporary increase and then decrease in the concentrations of vinyl chloride (VC) (a biodegradation product) to very low levels.

The TISR® system construction utilizes off-the-shelf modular components, promoting cost-efficiency, reusability, and a reduced carbon footprint. Waste heat can supplement or replace the solar setup, and remote monitoring through dashboard apps reduces operation and maintenance costs. TISR® projects typically achieve an average capital cost payback within 1 to 3 years due to accelerated rates of remediation.

When implementing TISR®, solar insolation and groundwater velocity must be considered for optimal equipment sizing and cycling. Depending on remedial goals and site history and conditions, the TISR® system and target temperatures may be designed to enhance specific remedial mechanisms (e.g. hydrolysis over bioremediation). Recently Ornelles et al.[3] developed an easy to use Excel-based model that can be used to optimize TISR® design and predict subsurface temperature changes over time. Frequent monitoring of the temperature and microbial community composition relative to targets is useful for evaluating treatment effectiveness and optimizing system performance. The system and target temperatures can be customized to enhance specific remedial mechanisms based on site conditions and goals.

Summary

TISR® is a cost-effective and adaptable technology that can be customized to address specific site challenges. It can be used as a standalone solution or be integrated with existing remediation strategies to enhance their effectiveness. TISR® is particularly effective in challenging hydrogeological conditions and can be optimized to suit specific treatment mechanisms. By shortening the active remediation timeframe, TISR® reduces lifecycle costs and minimizes the carbon footprint associated with the remediation process.

References

  1. ^ Divine, C., Munholland, J., Zardouzian, E., Justicia-Leon, S., Aspinall, J.V., Randhawa, D., Falta, R., Freedman, D., Becker, M., 2025. Thermal In Situ Sustainable Remediation to Enhance Biotic and Abiotic Reactions and Accelerate Remediation Timeframes, Final Report. Environmental Security Technology Certification Program (ESTCP), Project ER20-5028. Project Website  Final Report.pdf
  2. ^ 2.0 2.1 Munholland, J, Rosso, D., Randhawa, D., Devine, C., Pennington, A., 2024. Advances in Low-Temperature Thermal Remediation. In: García-Rincón, J., Gatsios, E., Lenhard, R.J., Atekwana, E.A., Naidu, R. (eds), Advances in the Characterisation and Remediation of Sites Contaminated with Petroleum Hydrocarbons, Chapter 18 pp. 623-653. Environmental Contamination Remediation and Management series, Springer Nature. doi: 10.1007/978-3-031-34447-3_18  Open Access Chapter
  3. ^ 3.0 3.1 Ornelles, A.D., Falta, R.W., Divine, C.E., 2023. A Design Tool for Solar Thermal Remediation Using Borehole Heat Exchangers. Ground Water, 61(2), pp. 245-254. doi: 10.1111/gwat.13265  Free download from NGWA
  4. ^ 4.0 4.1 Horst, J., Flanders, C., Klemmer, M., Randhawa, D.S., Rosso, D., 2018. Low-Temperature Thermal Remediation: Gaining Traction as a Green Remedial Alternative. Groundwater Monitoring and Remediation, 38(3), pp. 18-27. doi: 10.1111/gwmr.12295
  5. ^ Dettmer, K., 2002. A Discussion of the Effects of Thermal Remediation Treatments on Microbial Degradation Processes. U.S. Environmental Protection Agency, Office of Solid Waste and Emergency Response, Technology Innovation Office, Washington, DC. free report  free download from clu-in.org
  6. ^ Macbeth, T., Truex, M., Powell, T., Michalsen, M., 2012. Combining Low-Energy Electrical Resistance Heating with Biotic and Abiotic Reactions for Treatment of Chlorinated Solvent DNAPL Source Areas. Environmental Security Technology Certification Program (ESTCP) Project ER-200719 webpage  free download  Project Summary Presentation
  7. ^ Suthersan, S., Horst, J., Klemmer, M., Malone, D., 2012. Temperature-Activated Auto-Decomposition Reactions: An Under-Utilized In Situ Remediation Solution. Groundwater Monitoring and Remediation, 32(3), pp. 34-40. doi: 10.1111/j.1745-6592.2012.01407.x
  8. ^ Chen, F., Freedman, D.L., Falta, R.W., Murdoch, L.C., 2012. Henry's law constants of chlorinated solvents at elevated temperatures. Chemosphere, 86(2), pp.156-165. doi: 10.1016/j.chemosphere.2011.10.004

See Also

TISR® Explanation Video